CVE-2022-22155 Junos OS: ACX5448: FPC memory leak due to IPv6 neighbor flaps

Medium 6.5 Published Updated

An adjacent attacker can cause a memory leak in Juniper ACX5448 routers via IPv6 neighbor flaps, leading to a sustained Denial of Service.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Local or same network only
Victim action needed
Not needed
Fix
None listed

What is CVE-2022-22155?

CVE-2022-22155 is a medium-severity denial of service vulnerability in Juniper Junos, published on 19 Jan 2022. It can only be exploited from the same machine or local network, with no action from the victim.

Official description

An Uncontrolled Resource Consumption vulnerability in the handling of IPv6 neighbor state change events in Juniper Networks Junos OS allows an adjacent attacker to cause a memory leak in the Flexible PIC Concentrator (FPC) of an ACX5448 router. The continuous flapping of an IPv6 neighbor with specific timing will cause the FPC to run out of resources, leading to a Denial of Service (DoS) condition. Once the condition occurs, further packet processing will be impacted, creating a sustained Denial of Service (DoS) condition, requiring a manual PFE restart to restore service. The following error messages will be seen after the FPC resources have been exhausted: fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 fpc0 DNX_NH::dnx_nh_tag_ipv4_hw_install(),3135: dnx_nh_tag_ipv4_hw_install: BCM L3 Egress create object failed for NH 602 (-14:No resources for operation), BCM NH Params: unit:0 Port:41, L3_INTF:0 Flags: 0x40 This issue only affects the ACX5448 router. No other products or platforms are affected by this vulnerability. This issue affects Juniper Networks Junos OS on ACX5448: 18.4 versions prior to 18.4R3-S10; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R1-S8, 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S2; 19.4 versions prior to 19.4R1-S3, 19.4R2-S2, 19.4R3; 20.1 versions prior to 20.1R2; 20.2 versions prior to 20.2R1-S1, 20.2R2.

Weakness: CWE-401, CWE-772, CWE-400

Which versions are affected by CVE-2022-22155?

It affects 1 product.

Products include Juniper Junos.

How do I fix CVE-2022-22155?

No fix has been published for CVE-2022-22155 yet. Limit exposure of the affected software until one is available.

Upgrade, then put limits on request size, rate and nesting depth so one client cannot exhaust the service. More about Denial of service.

Is CVE-2022-22155 being exploited?

There is no known exploitation of CVE-2022-22155 in the wild and no public exploit code.

All Juniper Junos vulnerabilities

Sources

Also known as GHSA-f5xq-h855-6hmf.

Is CVE-2022-22155 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.