{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-22216 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22216 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22216 is a medium-severity vulnerability in Juniper Junos, published on 20 Jul 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-22216 and fix it if it is affected.\n\nWhat it is: CVE-2022-22216 is a medium-severity vulnerability in Juniper Junos, published on 20 Jul 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-22216 in the wild and no public exploit code.\n\nAffected product: Juniper Junos. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22216/ (Markdown: https://insights.sbomify.com/CVE-2022-22216/index.md)","id":"CVE-2022-22216","markdown":"https://insights.sbomify.com/CVE-2022-22216/index.md","name":"CVE-2022-22216","record":{"aliases":["GHSA-8r8m-8qj7-8fm2"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Juniper network switch","requires_auth":"none","summary":"Adjacent attackers can read sensitive system memory via improperly padded Ethernet packets on Juniper PTX and QFX devices.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"juniper","cpe":[{"product":"junos","vendor":"juniper"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"An Exposure of Sensitive Information to an Unauthorized Actor vulnerability in the PFE of Juniper Networks Junos OS on PTX Series and QFX10k Series allows an adjacent unauthenticated attacker to gain access to sensitive information. PTX1000 and PTX10000 Series, and QFX10000 Series and PTX5000 Series devices sometimes do not reliably pad Ethernet packets, and thus some packets can contain fragments of system memory or data from previous packets. This issue is also known as 'Etherleak' and often detected as CVE-2003-0001. This issue affects: Juniper Networks Junos OS on PTX1000 and PTX10000 Series: All versions prior to 18.4R3-S11; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S5, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S2; 20.4 versions prior to 20.4R3-S4; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R1-S1, 21.2R2. Juniper Networks Junos OS on QFX10000 Series and PTX5000 Series: All versions prior to 18.3R3-S6; 18.4 versions prior to 18.4R2-S9, 18.4R3-S10; 19.1 versions prior to 19.1R2-S3, 19.1R3-S7; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4; 19.3 versions prior to 19.3R3-S4; 19.4 versions prior to 19.4R2-S6, 19.4R3-S6; 20.1 versions prior to 20.1R3-S2; 20.2 versions prior to 20.2R3-S3; 20.3 versions prior to 20.3R3-S1; 20.4 versions prior to 20.4R3-S1; 21.1 versions prior to 21.1R2-S1, 21.1R3; 21.2 versions prior to 21.2R2.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Junos OS: PTX Series and QFX10000 Series: 'Etherleak' memory disclosure in Ethernet padding data","id":"CVE-2022-22216","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"juniper:junos","products":["juniper:junos"],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Junos OS: QFX10K Series: Denial of Service (DoS) upon receipt of crafted MLD packets on multi-homing ESI in VXLAN","id":"CVE-2022-22217"},"packages":[],"prev":{"headline":"Denial of service in Junos OS","id":"CVE-2022-22215"},"products":["Junos OS"],"published":"2022-07-20","related":[{"cvss_score":9.8,"headline":"Juniper Junos OS EX Series and SRX Series PHP External Variable Modification","id":"CVE-2023-36845","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":8.8,"headline":"Juniper Junos OS Path Traversal","id":"CVE-2020-1631","kev_date_added":"2022-03-25","published":"2020-05-04"},{"cvss_score":6.7,"headline":"Juniper Junos OS Improper Isolation or Compartmentalization","id":"CVE-2025-21590","kev_date_added":"2025-03-13","published":"2025-03-12"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36851","kev_date_added":"2023-11-13","published":"2023-09-26"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series PHP External Variable Modification","id":"CVE-2023-36844","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS SRX Series Missing Authentication for Critical Function","id":"CVE-2023-36846","kev_date_added":"2023-11-13","published":"2023-08-17"},{"cvss_score":5.3,"headline":"Juniper Junos OS EX Series Missing Authentication for Critical Function","id":"CVE-2023-36847","kev_date_added":"2023-11-13","published":"2023-08-17"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Juniper Networks"]},"summary":"Adjacent attackers can read sensitive system memory via improperly padded Ethernet packets on Juniper PTX and QFX devices.","url":"https://insights.sbomify.com/CVE-2022-22216/"}