CVE-2022-22234 Junos OS: EX2300 and EX3400 Series: One of more SFPs might become unavailable when the system is very busy

Medium 5.5 Published Updated

A local low-privilege attacker can cause a denial of service by triggering a race condition that makes SFPs appear unplugged during high system load.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Local or same network only
Victim action needed
Not needed
Fix
None listed

What is CVE-2022-22234?

CVE-2022-22234 is a medium-severity vulnerability in Juniper Junos, published on 18 Oct 2022. It can only be exploited from the same machine or local network, with no action from the victim.

Official description

An Improper Preservation of Consistency Between Independent Representations of Shared State vulnerability in the Packet Forwarding Engine (PFE) of Juniper Networks Junos OS allows a locally authenticated attacker with low privileges to cause a Denial of Service (DoS). If the device is very busy for example while executing a series of show commands on the CLI one or more SFPs might not be detected anymore. The system then changes its state to "unplugged" which is leading to traffic impact and at least a partial DoS. Once the system is less busy the port states return to their actual value. Indicators of compromise are log messages about unplugged SFPs and corresponding syspld messages without any physical or environmental cause. These can be checked by issuing the following commands: user@device# show log messages | match unplugged %PFE-6: fpc0 sfp-0/1/2 SFP unplugged %PFE-6: fpc0 sfp-0/1/3 SFP unplugged The following log messages will also be seen when this issue happens: fpc0 Error tvp_drv_syspld_read: syspld read failed for address <address> fpc0 Error[-1]:tvp_optics_presence_get - Syspld read failed for port <pic/port> fpc0 optics pres failed(-1) for pic <pic> port <port> fpc0 tvp_drv_syspld_read: i2c access retry count 200 This issue affects Juniper Networks Junos OS on EX2300 Series, EX3400 Series: All versions prior to 18.4R3-S11; 19.1 versions prior to 19.1R3-S9; 19.2 versions prior to 19.2R1-S9, 19.2R3-S5; 19.3 versions prior to 19.3R3-S6; 19.4 versions prior to 19.4R2-S7, 19.4R3-S8; 20.1 versions prior to 20.1R3-S4; 20.2 versions prior to 20.2R3-S4; 20.3 versions prior to 20.3R3-S4; 20.4 versions prior to 20.4R3-S3; 21.1 versions prior to 21.1R3-S1; 21.2 versions prior to 21.2R3; 21.3 versions prior to 21.3R2; 21.4 versions prior to 21.4R2.

Weakness: CWE-1250

Which versions are affected by CVE-2022-22234?

It affects 1 product.

Products include Juniper Junos.

How do I fix CVE-2022-22234?

No fix has been published for CVE-2022-22234 yet. Limit exposure of the affected software until one is available.

Is CVE-2022-22234 being exploited?

There is no known exploitation of CVE-2022-22234 in the wild and no public exploit code.

All Juniper Junos vulnerabilities