{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2022-22282 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22282 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22282 is a critical missing authorization vulnerability in SonicWall SMA1000, published on 13 May 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-22282 and fix it if it is affected.\n\nWhat it is: CVE-2022-22282 is a critical missing authorization vulnerability in SonicWall SMA1000, published on 13 May 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-22282 in the wild and no public exploit code.\n\nAffected product: SonicWall SMA1000. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22282/ (Markdown: https://insights.sbomify.com/CVE-2022-22282/index.md)","id":"CVE-2022-22282","markdown":"https://insights.sbomify.com/CVE-2022-22282/index.md","name":"CVE-2022-22282","record":{"aliases":["GHSA-8xpw-m3x3-rq75"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"SonicWall SMA1000","requires_auth":"none","summary":"Unauthorized actors can access restricted resources on SonicWall SMA1000 devices due to improper access control restrictions.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"sonicwall","cpe":[{"product":"sma_6200_firmware","vendor":"sonicwall"},{"product":"sma_6210_firmware","vendor":"sonicwall"},{"product":"sma_7200_firmware","vendor":"sonicwall"},{"product":"sma_7210_firmware","vendor":"sonicwall"},{"product":"sma_8000v_firmware","vendor":"sonicwall"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions incorrectly restricts access to a resource using HTTP connections from an unauthorized actor leading to Improper Access Control vulnerability.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SonicWall SMA1000","id":"CVE-2022-22282","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in Samsung Health","id":"CVE-2022-22283"},"packages":[],"prev":{"headline":"Memory corruption in SonicWall NetExtender Windows (32 and 64 bit) Client","id":"CVE-2022-22281"},"products":["SonicWall SMA1000"],"published":"2022-05-13","related":[{"cvss_score":7.5,"headline":"Hardcoded credentials in SonicWall SMA1000","id":"CVE-2022-1701","kev_date_added":null,"published":"2022-05-13"},{"cvss_score":6.1,"headline":"Open redirect in SonicWall SMA1000","id":"CVE-2022-1702","kev_date_added":null,"published":"2022-05-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["SonicWall"]},"summary":"Unauthorized actors can access restricted resources on SonicWall SMA1000 devices due to improper access control restrictions.","url":"https://insights.sbomify.com/CVE-2022-22282/"}