{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2022-22564 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22564 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22564 is a medium-severity vulnerability in Dell Unity, published on 14 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-22564 and fix it if it is affected.\n\nWhat it is: CVE-2022-22564 is a medium-severity vulnerability in Dell Unity, published on 14 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-22564 in the wild and no public exploit code.\n\nAffected product: Dell Unity. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22564/ (Markdown: https://insights.sbomify.com/CVE-2022-22564/index.md)","id":"CVE-2022-22564","markdown":"https://insights.sbomify.com/CVE-2022-22564/index.md","name":"CVE-2022-22564","record":{"aliases":["GHSA-cr87-3776-x62w"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Dell EMC Unity storage","requires_auth":"none","summary":"Remote attackers can exploit broken cryptography via MitM to obtain sensitive information from Dell EMC Unity storage systems.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"dell","cpe":[{"product":"emc_unity_operating_environment","vendor":"dell"},{"product":"emc_unity_xt_operating_environment","vendor":"dell"},{"product":"emc_unityvsa_operating_environment","vendor":"dell"}],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-327","name":"Use of a Broken or Risky Cryptographic Algorithm"}],"description":"Dell EMC Unity versions before 5.2.0.0.5.173 , use(es) broken cryptographic algorithm. A remote unauthenticated attacker could potentially exploit this vulnerability by performing MitM attacks and let attackers obtain sensitive information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in Unity","id":"CVE-2022-22564","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in PowerScale OneFS","id":"CVE-2022-22565"},"packages":[],"prev":{"headline":"Information disclosure in PowerScale OneFS","id":"CVE-2022-22563"},"products":["Unity"],"published":"2023-02-14","related":[{"cvss_score":9.8,"headline":"Auth bypass in VNX Control Station","id":"CVE-2021-36294","kev_date_added":null,"published":"2022-01-25"},{"cvss_score":8.6,"headline":"Path traversal in VNX2","id":"CVE-2021-36288","kev_date_added":null,"published":"2022-04-08"},{"cvss_score":7.8,"headline":"Information disclosure in VNX Control Station","id":"CVE-2021-36289","kev_date_added":null,"published":"2022-01-25"},{"cvss_score":7.8,"headline":"Information disclosure in Unity","id":"CVE-2019-3741","kev_date_added":null,"published":"2019-07-18"},{"cvss_score":7.8,"headline":"Privilege escalation in Dell EMC Unity","id":"CVE-2018-11064","kev_date_added":null,"published":"2018-10-05"},{"cvss_score":7.5,"headline":"Denial of service in Unity","id":"CVE-2020-29490","kev_date_added":null,"published":"2021-01-05"},{"cvss_score":7.5,"headline":"Denial of service in Unity","id":"CVE-2020-5319","kev_date_added":null,"published":"2020-02-06"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-20","vendors":["Dell"]},"summary":"Remote attackers can exploit broken cryptography via MitM to obtain sensitive information from Dell EMC Unity storage systems.","url":"https://insights.sbomify.com/CVE-2022-22564/"}