{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-22726 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22726 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22726 is a medium-severity path traversal vulnerability in EcoStruxure Power Monitoring Expert (Versions 2020 and prior), published on 4 Feb 2022. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-22726 and fix it if it is affected.\n\nWhat it is: CVE-2022-22726 is a medium-severity path traversal vulnerability in EcoStruxure Power Monitoring Expert (Versions 2020 and prior), published on 4 Feb 2022. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-22726 in the wild and no public exploit code.\n\nAffected product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22726/ (Markdown: https://insights.sbomify.com/CVE-2022-22726/index.md)","id":"CVE-2022-22726","markdown":"https://insights.sbomify.com/CVE-2022-22726/index.md","name":"CVE-2022-22726","record":{"aliases":["GHSA-rmf5-6wwh-2vw5"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Monitoring Expert","requires_auth":"low_privilege","summary":"Authenticated users can read arbitrary server files via improper input validation in EcoStruxure Power Monitoring Expert.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_power_monitoring_expert","vendor":"schneider-electric"}],"cvss":{"score":6.5,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A CWE-20: Improper Input Validation vulnerability exists that could allow arbitrary files on the server to be read by authenticated users through a limited operating system service account. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Path traversal in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22726","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Other in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22727"},"packages":[],"prev":{"headline":"Memory corruption in Easergy P3 (All versions prior to V30.205)","id":"CVE-2022-22725"},"products":["EcoStruxure Power Monitoring Expert (Versions 2020 and prior)"],"published":"2022-02-04","related":[{"cvss_score":9.8,"headline":"Deserialization in EcoStruxure Power Monitoring Expert","id":"CVE-2023-5391","kev_date_added":null,"published":"2023-10-04"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22727","kev_date_added":null,"published":"2022-02-04"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22826","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.8,"headline":"Code injection in n/a","id":"CVE-2021-22827","kev_date_added":null,"published":"2022-01-28"},{"cvss_score":8.5,"headline":"Deserialization in EcoStruxure™ Power Monitoring Expert (PME)","id":"CVE-2025-11739","kev_date_added":null,"published":"2026-03-10"},{"cvss_score":8.2,"headline":"Open redirect in EcoStruxure Power Monitoring Expert (PME)","id":"CVE-2023-5986","kev_date_added":null,"published":"2023-11-15"},{"cvss_score":6.7,"headline":"Auth bypass in EcoStruxure Power Monitoring Expert","id":"CVE-2023-28003","kev_date_added":null,"published":"2023-04-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Authenticated users can read arbitrary server files via improper input validation in EcoStruxure Power Monitoring Expert.","url":"https://insights.sbomify.com/CVE-2022-22726/"}