{"answers":{"affected":"It affects 8 products.","exploited":"There is no known exploitation of CVE-2022-22805 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22805 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22805 is a critical memory corruption vulnerability in Schneider Electric SmartConnect, published on 9 Mar 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-22805 and fix it if it is affected.\n\nWhat it is: CVE-2022-22805 is a critical memory corruption vulnerability in Schneider Electric SmartConnect, published on 9 Mar 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-22805 in the wild and no public exploit code.\n\nAffected product: Schneider Electric SmartConnect. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22805/ (Markdown: https://insights.sbomify.com/CVE-2022-22805/index.md)","id":"CVE-2022-22805","markdown":"https://insights.sbomify.com/CVE-2022-22805/index.md","name":"CVE-2022-22805","record":{"aliases":["GHSA-w827-q88j-8c47"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Schneider SmartConnect","requires_auth":"none","summary":"Remote attackers can execute arbitrary code via a buffer overflow in TLS packet reassembly on Schneider SmartConnect devices.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"scl_series_1029_ups_firmware","vendor":"schneider-electric"},{"product":"scl_series_1030_ups_firmware","vendor":"schneider-electric"},{"product":"scl_series_1036_ups_firmware","vendor":"schneider-electric"},{"product":"scl_series_1037_ups_firmware","vendor":"schneider-electric"},{"product":"smc_series_1018_ups_firmware","vendor":"schneider-electric"},{"product":"smt_series_1015_ups_firmware","vendor":"schneider-electric"},{"product":"smtl_series_1026_ups_firmware","vendor":"schneider-electric"},{"product":"smx_series_1031_ups_firmware","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in SmartConnect","id":"CVE-2022-22805","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Auth bypass in SmartConnect","id":"CVE-2022-22806"},"packages":[],"prev":{"headline":"Cross-site scripting in EcoStruxure Power Monitoring Expert (Versions 2020 and prior)","id":"CVE-2022-22804"},"products":["SmartConnect"],"published":"2022-03-09","related":[{"cvss_score":9.8,"headline":"Auth bypass in SmartConnect","id":"CVE-2022-22806","kev_date_added":null,"published":"2022-03-09"},{"cvss_score":8.9,"headline":"Auth bypass in APC Smart-UPS","id":"CVE-2022-0715","kev_date_added":null,"published":"2022-03-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Schneider Electric"]},"summary":"Remote attackers can execute arbitrary code via a buffer overflow in TLS packet reassembly on Schneider SmartConnect devices.","url":"https://insights.sbomify.com/CVE-2022-22805/"}