CVE-2022-22807 Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
Attackers can trick users into modifying settings or accounts via iframes in the web interface of EcoStruxure EV Charging Expert.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- A user has to click or open something
- Fix
- None listed
What is CVE-2022-22807?
CVE-2022-22807 is a high-severity vulnerability in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.
Official description
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
Weakness: CWE-1021
Which versions are affected by CVE-2022-22807?
It affects 7 products.
Products include Schneider-Electric Hmibscea53d1edb Firmware, Schneider-Electric Hmibscea53d1edl Firmware, Schneider-Electric Hmibscea53d1edm Firmware, Schneider-Electric Hmibscea53d1eds Firmware, Schneider-Electric Hmibscea53d1eml Firmware, Schneider-Electric Hmibscea53d1esm Firmware and 1 more.
How do I fix CVE-2022-22807?
No fix has been published for CVE-2022-22807 yet. Limit exposure of the affected software until one is available.
Is CVE-2022-22807 being exploited?
There is no known exploitation of CVE-2022-22807 in the wild and no public exploit code.
Other vulnerabilities in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
Sources
Also known as GHSA-jr23-8cgm-x898.