{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2022-22807 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22807 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22807 is a high-severity vulnerability in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-22807 and fix it if it is affected.\n\nWhat it is: CVE-2022-22807 is a high-severity vulnerability in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-22807 in the wild and no public exploit code.\n\nAffected product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22807/ (Markdown: https://insights.sbomify.com/CVE-2022-22807/index.md)","id":"CVE-2022-22807","markdown":"https://insights.sbomify.com/CVE-2022-22807/index.md","name":"CVE-2022-22807","record":{"aliases":["GHSA-jr23-8cgm-x898"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charging management","requires_auth":"none","summary":"Attackers can trick users into modifying settings or accounts via iframes in the web interface of EcoStruxure EV Charging Expert.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"hmibscea53d1edb_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1edl_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1edm_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1eds_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1eml_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1esm_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1ess_firmware","vendor":"schneider-electric"}],"cvss":{"score":7.4,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N","version":"3.1"},"cwes":[{"id":"CWE-1021","name":"Improper Restriction of Rendered UI Layers or Frames"}],"description":"A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","id":"CVE-2022-22807","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","id":"CVE-2022-22808"},"packages":[],"prev":{"headline":"Auth bypass in SmartConnect","id":"CVE-2022-22806"},"products":["EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)"],"published":"2022-02-09","related":[{"cvss_score":8.8,"headline":"Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","id":"CVE-2022-22808","kev_date_added":null,"published":"2022-02-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Attackers can trick users into modifying settings or accounts via iframes in the web interface of EcoStruxure EV Charging Expert.","url":"https://insights.sbomify.com/CVE-2022-22807/"}