{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2022-22808 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-22808 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-22808 is a high-severity vulnerability in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-22808 and fix it if it is affected.\n\nWhat it is: CVE-2022-22808 is a high-severity vulnerability in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-22808 in the wild and no public exploit code.\n\nAffected product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-22808/ (Markdown: https://insights.sbomify.com/CVE-2022-22808/index.md)","id":"CVE-2022-22808","markdown":"https://insights.sbomify.com/CVE-2022-22808/index.md","name":"CVE-2022-22808","record":{"aliases":["GHSA-p6hc-w7h4-q55x"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"EV charging management","requires_auth":"none","summary":"Remote attackers can bypass CSRF protections to gain unauthorized access to the EcoStruxure EV Charging Expert system.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"hmibscea53d1edb_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1edl_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1edm_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1eds_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1eml_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1esm_firmware","vendor":"schneider-electric"},{"product":"hmibscea53d1ess_firmware","vendor":"schneider-electric"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","id":"CVE-2022-22808","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)","id":"CVE-2022-22809"},"packages":[],"prev":{"headline":"Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","id":"CVE-2022-22807"},"products":["EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)"],"published":"2022-02-09","related":[{"cvss_score":7.4,"headline":"Cross-site request forgery in EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)","id":"CVE-2022-22807","kev_date_added":null,"published":"2022-02-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Remote attackers can bypass CSRF protections to gain unauthorized access to the EcoStruxure EV Charging Expert system.","url":"https://insights.sbomify.com/CVE-2022-22808/"}