{"answers":{"affected":"It affects 1 product.","exploited":"It is not confirmed as exploited in the wild, but public exploit code for CVE-2022-23102 exists.","fix":"No fix has been published for CVE-2022-23102 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-23102 is a medium-severity vulnerability in Siemens Sinema Remote Connect Server, published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-23102 and fix it if it is affected.\n\nWhat it is: CVE-2022-23102 is a medium-severity vulnerability in Siemens Sinema Remote Connect Server, published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: It is not confirmed as exploited in the wild, but public exploit code for CVE-2022-23102 exists.\n\nAffected product: Siemens Sinema Remote Connect Server. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-23102/ (Markdown: https://insights.sbomify.com/CVE-2022-23102/index.md)","id":"CVE-2022-23102","markdown":"https://insights.sbomify.com/CVE-2022-23102/index.md","name":"CVE-2022-23102","record":{"aliases":["GHSA-9wrg-64cr-9jvf"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"SINEMA Remote Connect Server","requires_auth":"none","summary":"An attacker can trick authenticated users into clicking malicious links leading to phishing attacks via an open redirect vulnerability in Siemens SINEMA Remote Connect Server.","user_interaction":"required","vuln_class":"open_redirect"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"sinema_remote_connect_server","vendor":"siemens"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-601","name":"URL Redirection to Untrusted Site"}],"description":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":1,"refs":[{"date":null,"kind":"nuclei","ref":"http/cves/2022/CVE-2022-23102.yaml","stars":null,"title":"SINEMA Remote Connect Server \u003c V2.0 - Open Redirect"}],"tier":"weaponised"},"has_fix":null,"headline":"Open redirect in SINEMA Remote Connect Server","id":"CVE-2022-23102","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"siemens:sinema_remote_connect_server","products":["siemens:sinema_remote_connect_server"],"type":"open_redirect","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Memory corruption in LinkHub Mesh Wifi","id":"CVE-2022-23103"},"packages":[],"prev":{"headline":"Cross-site scripting in n/a","id":"CVE-2022-23101"},"products":["SINEMA Remote Connect Server"],"published":"2022-02-09","related":[{"cvss_score":9.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2022-32257","kev_date_added":null,"published":"2024-03-12"},{"cvss_score":9.8,"headline":"Auth bypass in SINEMA Remote Connect Server","id":"CVE-2019-13918","kev_date_added":null,"published":"2019-09-13"},{"cvss_score":9.3,"headline":"Privilege escalation in SINEMA Remote Connect Server","id":"CVE-2024-39872","kev_date_added":null,"published":"2024-07-09"},{"cvss_score":8.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2022-32251","kev_date_added":null,"published":"2022-06-14"},{"cvss_score":8.8,"headline":"Command injection in SINEMA Remote Connect Server","id":"CVE-2022-32262","kev_date_added":null,"published":"2022-06-14"},{"cvss_score":8.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2020-25239","kev_date_added":null,"published":"2021-03-15"},{"cvss_score":8.8,"headline":"Missing authorization in SINEMA Remote Connect Server","id":"CVE-2020-25240","kev_date_added":null,"published":"2021-03-15"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"},{"class":"attribution","licence":"MIT","name":"Nuclei templates"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Siemens"]},"summary":"An attacker can trick authenticated users into clicking malicious links leading to phishing attacks via an open redirect vulnerability in Siemens SINEMA Remote Connect Server.","url":"https://insights.sbomify.com/CVE-2022-23102/"}