{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2022-23127 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-23127 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-23127 is a medium-severity cross-site scripting vulnerability in Mitsubishi Electric MC Works64; ICONICS MobileHMI, published on 21 Jan 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-23127 and fix it if it is affected.\n\nWhat it is: CVE-2022-23127 is a medium-severity cross-site scripting vulnerability in Mitsubishi Electric MC Works64; ICONICS MobileHMI, published on 21 Jan 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-23127 in the wild and no public exploit code.\n\nAffected product: Mitsubishi Electric MC Works64; ICONICS MobileHMI. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-23127/ (Markdown: https://insights.sbomify.com/CVE-2022-23127/index.md)","id":"CVE-2022-23127","markdown":"https://insights.sbomify.com/CVE-2022-23127/index.md","name":"CVE-2022-23127","record":{"aliases":["GHSA-3ccx-8rq3-28hx"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["account_takeover","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA HMI software","requires_auth":"none","summary":"Remote attackers can steal authentication credentials via XSS in Mitsubishi Electric MC Works64 and ICONICS MobileHMI, enabling unauthorized system access.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[{"product":"mobilehmi","vendor":"iconics"},{"product":"mc_works64","vendor":"mitsubishielectric"}],"cvss":{"score":6.1,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Cross-site Scripting vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS MobileHMI versions 10.96.2 and prior allows a remote unauthenticated attacker to gain authentication information of an MC Works64 or MobileHMI and perform any operation using the acquired authentication information, by injecting a malicious script in the URL of a monitoring screen delivered from the MC Works64 server or MobileHMI server to an application for mobile devices and leading a legitimate user to access this URL.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in Mitsubishi Electric MC Works64; ICONICS MobileHMI","id":"CVE-2022-23127","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Auth bypass in Mitsubishi Electric MC Works64; ICONICS GENESIS64; ICONICS Hyper Historian; ICONICS AnalytiX; ICONICS MobileHMI","id":"CVE-2022-23128"},"packages":[],"prev":{"headline":"Auth bypass in n/a","id":"CVE-2022-23126"},"products":["Mitsubishi Electric MC Works64; ICONICS MobileHMI"],"published":"2022-01-21","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Remote attackers can steal authentication credentials via XSS in Mitsubishi Electric MC Works64 and ICONICS MobileHMI, enabling unauthorized system access.","url":"https://insights.sbomify.com/CVE-2022-23127/"}