{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-23235 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-23235 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-23235 is a medium-severity vulnerability in Netapp Active Iq Unified Manager, published on 25 Aug 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-23235 and fix it if it is affected.\n\nWhat it is: CVE-2022-23235 is a medium-severity vulnerability in Netapp Active Iq Unified Manager, published on 25 Aug 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-23235 in the wild and no public exploit code.\n\nAffected product: Netapp Active Iq Unified Manager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-23235/ (Markdown: https://insights.sbomify.com/CVE-2022-23235/index.md)","id":"CVE-2022-23235","markdown":"https://insights.sbomify.com/CVE-2022-23235/index.md","name":"CVE-2022-23235","record":{"aliases":["GHSA-7677-xwx4-r4m4"],"analysis":{"component_type":"server_software","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"NetApp Active IQ Unified Manager","requires_auth":"none","summary":"Attackers can discover sensitive cluster and node information via telemetry data sent even when AutoSupport is disabled in NetApp Active IQ Unified Manager.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"netapp","cpe":[{"product":"active_iq_unified_manager","vendor":"netapp"}],"cvss":{"score":5.3,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[],"description":"Active IQ Unified Manager for VMware vSphere, Linux, and Microsoft Windows versions prior to 9.10P1 are susceptible to a vulnerability which could allow an attacker to discover cluster, node and Active IQ Unified Manager specific information via AutoSupport telemetry data that is sent even when AutoSupport has been disabled.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in Active IQ Unified Manager","id":"CVE-2022-23235","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"netapp:active_iq_unified_manager","products":["netapp:active_iq_unified_manager"],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Information disclosure in E-Series SANtricity OS Controller Software 11.x","id":"CVE-2022-23236"},"packages":[],"prev":{"headline":"Information disclosure in SnapCenter","id":"CVE-2022-23234"},"products":["Active IQ Unified Manager"],"published":"2022-08-25","related":[{"cvss_score":9.8,"headline":"Spring Security authorization rules can be bypassed via forward or include dispatcher types","id":"CVE-2022-31692","kev_date_added":null,"published":"2022-10-31"},{"cvss_score":9.8,"headline":"Use after free in systemd-resolved","id":"CVE-2022-2526","kev_date_added":null,"published":"2022-09-09"},{"cvss_score":9.8,"headline":"Authorization bypass in Spring Security","id":"CVE-2022-22978","kev_date_added":null,"published":"2022-05-19"},{"cvss_score":9.8,"headline":"Code injection in Node","id":"CVE-2021-22931","kev_date_added":null,"published":"2021-08-16"},{"cvss_score":9,"headline":"Code injection in Java","id":"CVE-2018-2938","kev_date_added":null,"published":"2018-07-18"},{"cvss_score":8.3,"headline":"Code injection in Java","id":"CVE-2018-2941","kev_date_added":null,"published":"2018-07-18"},{"cvss_score":8.3,"headline":"Code injection in Java","id":"CVE-2018-2942","kev_date_added":null,"published":"2018-07-18"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Attackers can discover sensitive cluster and node information via telemetry data sent even when AutoSupport is disabled in NetApp Active IQ Unified Manager.","url":"https://insights.sbomify.com/CVE-2022-23235/"}