CVE-2022-23450 Deserialization in SIMATIC Energy Manager Basic
Unauthenticated attackers can execute arbitrary code with SYSTEM privileges via insecure deserialization in Siemens SIMATIC Energy Manager.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2022-23450?
CVE-2022-23450 is a critical unsafe deserialization vulnerability in Siemens SIMATIC Energy Manager Basic, published on 12 Apr 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
Weakness: CWE-502
Which versions are affected by CVE-2022-23450?
It affects 2 products.
Products include Siemens Simatic Energy Manager Basic, Siemens Simatic Energy Manager Pro.
How do I fix CVE-2022-23450?
No fix has been published for CVE-2022-23450 yet. Limit exposure of the affected software until one is available.
Upgrade, and only deserialise data from trusted sources or with an allow-list of types. More about Unsafe deserialization.
Is CVE-2022-23450 being exploited?
There is no known exploitation of CVE-2022-23450 in the wild and no public exploit code.
Other vulnerabilities in Siemens SIMATIC Energy Manager Basic
Sources
Also known as GHSA-xrj9-8xhq-9gjh.