{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-23704 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-23704 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-23704 is a high-severity vulnerability in HPE Integrated Lights-Out 4 (iLO 4), published on 9 May 2022."},"fix_prompt":"Check this codebase for CVE-2022-23704 and fix it if it is affected.\n\nWhat it is: CVE-2022-23704 is a high-severity vulnerability in HPE Integrated Lights-Out 4 (iLO 4), published on 9 May 2022. \nExploitation: There is no known exploitation of CVE-2022-23704 in the wild and no public exploit code.\n\nAffected product: HPE Integrated Lights-Out 4 (iLO 4). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-23704/ (Markdown: https://insights.sbomify.com/CVE-2022-23704/index.md)","id":"CVE-2022-23704","markdown":"https://insights.sbomify.com/CVE-2022-23704/index.md","name":"CVE-2022-23704","record":{"aliases":["GHSA-jv6q-f63c-9wf2"],"analysis":null,"analysis_generated_by":null,"assigner":"hpe","cpe":[{"product":"integrated_lights-out_4","vendor":"hp"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[],"description":"A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4). The vulnerability could allow remote Denial of Service. The vulnerability is resolved in Integrated Lights-Out 4 (iLO 4) 2.80 and later.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"A potential security vulnerability has been identified in Integrated Lights-Out 4 (iLO 4).","id":"CVE-2022-23704","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":null,"year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"File upload in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays","id":"CVE-2022-23705"},"packages":[],"prev":{"headline":"Other in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays","id":"CVE-2022-23703"},"products":["HPE Integrated Lights-Out 4 (iLO 4)"],"published":"2022-05-09","related":[{"cvss_score":8.3,"headline":"Cross-site scripting in Integrated Lights-Out","id":"CVE-2023-28083","kev_date_added":null,"published":"2023-03-20"},{"cvss_score":6.8,"headline":"Information disclosure in n/a","id":"CVE-2013-4843","kev_date_added":null,"published":"2013-11-16"},{"cvss_score":6.7,"headline":"Memory corruption in HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers","id":"CVE-2021-29202","kev_date_added":null,"published":"2021-05-25"},{"cvss_score":5.3,"headline":"Information disclosure in HPE ProLiant Servers, Apollo Products, Converged Systems, and Synergy Compute Modules with Integrated Lights-Out 5 (iLO 5), or Integrated Lights-Out 4 (iLO 4)","id":"CVE-2020-7202","kev_date_added":null,"published":"2021-01-05"},{"cvss_score":4.8,"headline":"Cross-site scripting in HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers","id":"CVE-2021-29201","kev_date_added":null,"published":"2021-05-25"},{"cvss_score":4.8,"headline":"Cross-site scripting in HPE Integrated Lights-Out 4 (iLO 4) For HPE Gen9 servers; HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers","id":"CVE-2021-29204","kev_date_added":null,"published":"2021-05-25"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":null,"url":"https://insights.sbomify.com/CVE-2022-23704/"}