CVE-2022-24296 Weak cryptography in Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A

High 7.5 Published Updated

Remote attackers can sniff encrypted communications to disclose sensitive data from Mitsubishi air conditioning systems due to weak cryptography.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2022-24296?

CVE-2022-24296 is a high-severity vulnerability in Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A, published on 8 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.

Weakness: CWE-327

Which versions are affected by CVE-2022-24296?

It affects 20 products.

Products include Mitsubishi Ae-200a Firmware, Mitsubishi Ae-200e Firmware, Mitsubishi Ae-200j Firmware, Mitsubishi Ae-50a Firmware, Mitsubishi Ae-50e Firmware, Mitsubishi Ae-50j Firmware and 14 more.

How do I fix CVE-2022-24296?

No fix has been published for CVE-2022-24296 yet. Limit exposure of the affected software until one is available.

Is CVE-2022-24296 being exploited?

There is no known exploitation of CVE-2022-24296 in the wild and no public exploit code.