{"answers":{"affected":"It affects 20 products.","exploited":"There is no known exploitation of CVE-2022-24296 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-24296 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-24296 is a high-severity vulnerability in Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A, published on 8 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-24296 and fix it if it is affected.\n\nWhat it is: CVE-2022-24296 is a high-severity vulnerability in Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A, published on 8 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-24296 in the wild and no public exploit code.\n\nAffected product: Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-24296/ (Markdown: https://insights.sbomify.com/CVE-2022-24296/index.md)","id":"CVE-2022-24296","markdown":"https://insights.sbomify.com/CVE-2022-24296/index.md","name":"CVE-2022-24296","record":{"aliases":["GHSA-9mwc-7fwx-973c"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Air Conditioning System","requires_auth":"none","summary":"Remote attackers can sniff encrypted communications to disclose sensitive data from Mitsubishi air conditioning systems due to weak cryptography.","user_interaction":"not_required","vuln_class":"weak_cryptography"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Mitsubishi","cpe":[{"product":"ae-200a_firmware","vendor":"mitsubishi"},{"product":"ae-200e_firmware","vendor":"mitsubishi"},{"product":"ae-200j_firmware","vendor":"mitsubishi"},{"product":"ae-50a_firmware","vendor":"mitsubishi"},{"product":"ae-50e_firmware","vendor":"mitsubishi"},{"product":"ae-50j_firmware","vendor":"mitsubishi"},{"product":"ag-150a-a_firmware","vendor":"mitsubishi"},{"product":"ag-150a-j_firmware","vendor":"mitsubishi"},{"product":"eb-50gu-a_firmware","vendor":"mitsubishi"},{"product":"eb-50gu-j_firmware","vendor":"mitsubishi"},{"product":"ew-50a_firmware","vendor":"mitsubishi"},{"product":"ew-50e_firmware","vendor":"mitsubishi"},{"product":"ew-50j_firmware","vendor":"mitsubishi"},{"product":"g-150ad_firmware","vendor":"mitsubishi"},{"product":"gb-50a_firmware","vendor":"mitsubishi"},{"product":"gb-50ada-a_firmware","vendor":"mitsubishi"},{"product":"gb-50ada-j_firmware","vendor":"mitsubishi"},{"product":"te-200a_firmware","vendor":"mitsubishi"},{"product":"te-50a_firmware","vendor":"mitsubishi"},{"product":"tw-50a_firmware","vendor":"mitsubishi"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-327","name":"Use of a Broken or Risky Cryptographic Algorithm"}],"description":"Use of a Broken or Risky Cryptographic Algorithm vulnerability in Air Conditioning System G-150AD Ver. 3.21 and prior, Air Conditioning System AG-150A-A Ver. 3.21 and prior, Air Conditioning System AG-150A-J Ver. 3.21 and prior, Air Conditioning System GB-50AD Ver. 3.21 and prior, Air Conditioning System GB-50ADA-A Ver. 3.21 and prior, Air Conditioning System GB-50ADA-J Ver. 3.21 and prior, Air Conditioning System EB-50GU-A Ver. 7.10 and prior, Air Conditioning System EB-50GU-J Ver. 7.10 and prior, Air Conditioning System AE-200J Ver. 7.97 and prior, Air Conditioning System AE-200A Ver. 7.97 and prior, Air Conditioning System AE-200E Ver. 7.97 and prior, Air Conditioning System AE-50J Ver. 7.97 and prior, Air Conditioning System AE-50A Ver. 7.97 and prior, Air Conditioning System AE-50E Ver. 7.97 and prior, Air Conditioning System EW-50J Ver. 7.97 and prior, Air Conditioning System EW-50A Ver. 7.97 and prior, Air Conditioning System EW-50E Ver. 7.97 and prior, Air Conditioning System TE-200A Ver. 7.97 and prior, Air Conditioning System TE-50A Ver. 7.97 and prior and Air Conditioning System TW-50A Ver. 7.97 and prior allows a remote unauthenticated attacker to cause a disclosure of encrypted message of the air conditioning systems by sniffing encrypted communications.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Weak cryptography in Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A","id":"CVE-2022-24296","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"weak_cryptography","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Privilege escalation in Intel(R) NUCs","id":"CVE-2022-24297"},"packages":[],"prev":{"headline":"Command injection in Okta Advanced Server Access Client","id":"CVE-2022-24295"},"products":["Air Conditioning System G-150AD; Air Conditioning System AG-150A-A; Air Conditioning System AG-150A-J; Air Conditioning System GB-50AD; Air Conditioning System GB-50ADA-A; Air Conditioning System GB-50ADA-J; Air Conditioning System EB-50GU-A; Air Conditioning System EB-50GU-J; Air Conditioning System AE-200J; Air Conditioning System AE-200A; Air Conditioning System AE-200E; Air Conditioning System AE-50J; Air Conditioning System AE-50A; Air Conditioning System AE-50E; Air Conditioning System EW-50J; Air Conditioning System EW-50A; Air Conditioning System EW-50E; Air Conditioning System TE-200A; Air Conditioning System TE-50A; Air Conditioning System TW-50A"],"published":"2022-06-08","related":[{"cvss_score":8.2,"headline":"XML external entity in Air Conditioning System/Centralized Controllers G-50A; GB-50A; GB-24A; AG-150A-A; AG-150A-J; GB-50ADA-A; GB-50ADA-J; EB-50GU-A; EB-50GU-J; AE-200A; AE-200E; AE-50A; AE-50E; EW-50A; EW-50E; TE-200A; TE-50A; TW-50A; CMS-RMD-J; Air Conditioning System/Expansion Controllers PAC-YG50ECA; Air Conditioning System/BM adapter BAC-HD150","id":"CVE-2021-20595","kev_date_added":null,"published":"2021-07-13"},{"cvss_score":7.1,"headline":"Auth bypass in Air Conditioning System/Centralized Controllers G-50A; GB-50A; AG-150A-A; AG-150A-J; GB-50ADA-A; GB-50ADA-J; EB-50GU-A; EB-50GU-J; AE-200A; AE-200E; AE-50A; AE-50E; EW-50A; EW-50E; TE-200A; TE-50A; TW-50A; CMS-RMD-J; Air Conditioning System/Expansion Controllers PAC-YG50ECA","id":"CVE-2021-20593","kev_date_added":null,"published":"2021-07-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Remote attackers can sniff encrypted communications to disclose sensitive data from Mitsubishi air conditioning systems due to weak cryptography.","url":"https://insights.sbomify.com/CVE-2022-24296/"}