{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-24315 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-24315 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-24315 is a high-severity denial of service vulnerability in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-24315 and fix it if it is affected.\n\nWhat it is: CVE-2022-24315 is a high-severity denial of service vulnerability in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-24315 in the wild and no public exploit code.\n\nAffected product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-24315/ (Markdown: https://insights.sbomify.com/CVE-2022-24315/index.md)","id":"CVE-2022-24315","markdown":"https://insights.sbomify.com/CVE-2022-24315/index.md","name":"CVE-2022-24315","record":{"aliases":["GHSA-wrrm-pwrp-4mqm"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA Data Server","requires_auth":"none","summary":"An attacker can cause denial of service in the SCADA Data Server by repeatedly sending specially crafted messages.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"interactive_graphical_scada_system_data_server","vendor":"schneider-electric"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-125","name":"Out-of-bounds Read"}],"description":"A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Denial of service in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24315","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2022"},"n_packages":0,"n_references":2,"next":{"headline":"Information disclosure in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24316"},"packages":[],"prev":{"headline":"Memory corruption in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24314"},"products":["Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)"],"published":"2022-02-09","related":[{"cvss_score":9.8,"headline":"Integer overflow in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24310","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":9.8,"headline":"Path traversal in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24311","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":9.8,"headline":"Path traversal in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24312","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":9.8,"headline":"Memory corruption in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24313","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":7.5,"headline":"Memory corruption in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24314","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":7.5,"headline":"Information disclosure in Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)","id":"CVE-2022-24316","kev_date_added":null,"published":"2022-02-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"An attacker can cause denial of service in the SCADA Data Server by repeatedly sending specially crafted messages.","url":"https://insights.sbomify.com/CVE-2022-24315/"}