{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2022-24320 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-24320 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-24320 is a medium-severity vulnerability in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-24320 and fix it if it is affected.\n\nWhat it is: CVE-2022-24320 is a medium-severity vulnerability in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions), published on 9 Feb 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-24320 in the wild and no public exploit code.\n\nAffected product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-24320/ (Markdown: https://insights.sbomify.com/CVE-2022-24320/index.md)","id":"CVE-2022-24320","markdown":"https://insights.sbomify.com/CVE-2022-24320/index.md","name":"CVE-2022-24320","record":{"aliases":["GHSA-r79f-wxvr-pq9r"],"analysis":{"component_type":"ics_ot","fix_type":"no_fix_stated","impacts":["data_read","security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA software","requires_auth":"none","summary":"Improper certificate validation in Geo SCADA allows Man-in-the-Middle attacks, enabling interception of client-server communications.","user_interaction":"not_required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"clearscada","vendor":"schneider-electric"},{"product":"ecostruxure_geo_scada_expert_2019","vendor":"schneider-electric"},{"product":"ecostruxure_geo_scada_expert_2020","vendor":"schneider-electric"}],"cvss":{"score":5.9,"severity":"medium","source":"nvd","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-295","name":"Improper Certificate Validation"}],"description":"A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24320","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2022"},"n_packages":0,"n_references":2,"next":{"headline":"Denial of service in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24321"},"packages":[],"prev":{"headline":"Other in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24319"},"products":["ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)"],"published":"2022-02-09","related":[{"cvss_score":7.8,"headline":"Missing authorization in EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)","id":"CVE-2019-6854","kev_date_added":null,"published":"2020-01-06"},{"cvss_score":7.5,"headline":"Weak cryptography in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24318","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":7.5,"headline":"Denial of service in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24321","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":6.7,"headline":"Weak cryptography in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior)","id":"CVE-2021-22741","kev_date_added":null,"published":"2021-05-26"},{"cvss_score":5.9,"headline":"Other in ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)","id":"CVE-2022-24319","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":5.3,"headline":"Other in ClearSCADA","id":"CVE-2023-0595","kev_date_added":null,"published":"2023-02-24"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Improper certificate validation in Geo SCADA allows Man-in-the-Middle attacks, enabling interception of client-server communications.","url":"https://insights.sbomify.com/CVE-2022-24320/"}