{"answers":{"affected":"It affects 6 products.","exploited":"There is no known exploitation of CVE-2022-2513 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-2513 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-2513 is a high-severity vulnerability in Hitachi Energy 650 Connectivity Package, published on 22 Nov 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-2513 and fix it if it is affected.\n\nWhat it is: CVE-2022-2513 is a high-severity vulnerability in Hitachi Energy 650 Connectivity Package, published on 22 Nov 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-2513 in the wild and no public exploit code.\n\nAffected product: Hitachi Energy 650 Connectivity Package. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-2513/ (Markdown: https://insights.sbomify.com/CVE-2022-2513/index.md)","id":"CVE-2022-2513","markdown":"https://insights.sbomify.com/CVE-2022-2513/index.md","name":"CVE-2022-2513","record":{"aliases":["GHSA-rrwm-2vxq-5x2h"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["data_read","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Hitachi Energy IED software","requires_auth":"none","summary":"Attackers with backup file or host access can read cleartext IED credentials, enabling unauthorized configuration changes or denial of service.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Hitachi Energy","cpe":[{"product":"650connectivitypackage","vendor":"hitachienergy"},{"product":"670connectivitypackage","vendor":"hitachienergy"},{"product":"gms600connectivitypackage","vendor":"hitachienergy"},{"product":"pcm600","vendor":"hitachienergy"},{"product":"pwc600connectivitypackage","vendor":"hitachienergy"},{"product":"sam600ioconnectivitypackage","vendor":"hitachienergy"}],"cvss":{"score":7.1,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"}],"description":"A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 product included in the versions listed below, where IEDs credentials are stored in a cleartext format in the PCM600 database and logs files. An attacker having get access to the exported backup file can exploit the vulnerability and obtain user credentials of the IEDs. Additionally, an attacker with administrator access to the PCM600 host machine can obtain other user credentials by analyzing database log files. The credentials may be used to perform unauthorized modifications such as loading incorrect configurations, reboot the IEDs or cause a denial-of-service on the IEDs.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in 650 Connectivity Package","id":"CVE-2022-2513","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site Scripting (XSS) - Reflected in beancount/fava","id":"CVE-2022-2514"},"packages":[],"prev":{"headline":"Information disclosure in GitLab","id":"CVE-2022-2512"},"products":["650 Connectivity Package","670 Connectivity Package","GMS600 Connectivity Package","PCM600","PWC600 Connectivity Package","SAM600-IO Connectivity Package"],"published":"2022-11-22","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-08-27","vendors":["Hitachi Energy"]},"summary":"Attackers with backup file or host access can read cleartext IED credentials, enabling unauthorized configuration changes or denial of service.","url":"https://insights.sbomify.com/CVE-2022-2513/"}