{"answers":{"affected":"It affects 24 products.","exploited":"There is no known exploitation of CVE-2022-25754 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-25754 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-25754 is a high-severity vulnerability in Siemens SCALANCE X302-7 EEC (230V), published on 12 Apr 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-25754 and fix it if it is affected.\n\nWhat it is: CVE-2022-25754 is a high-severity vulnerability in Siemens SCALANCE X302-7 EEC (230V), published on 12 Apr 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-25754 in the wild and no public exploit code.\n\nAffected product: Siemens SCALANCE X302-7 EEC (230V). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-25754/ (Markdown: https://insights.sbomify.com/CVE-2022-25754/index.md)","id":"CVE-2022-25754","markdown":"https://insights.sbomify.com/CVE-2022-25754/index.md","name":"CVE-2022-25754","record":{"aliases":["GHSA-pm3p-vw5f-jpj5"],"analysis":{"component_type":"network_device","fix_type":"patch","impacts":["security_bypass"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SCALANCE switch","requires_auth":"none","summary":"Cross-site request forgery vulnerability in Siemens SCALANCE switches allows attackers to perform unauthorized actions on behalf of authenticated users.","user_interaction":"required","vuln_class":"csrf"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"scalance_x302-7eec_firmware","vendor":"siemens"},{"product":"scalance_x304-2fe_firmware","vendor":"siemens"},{"product":"scalance_x306-1ldfe_firmware","vendor":"siemens"},{"product":"scalance_x307-2eec_firmware","vendor":"siemens"},{"product":"scalance_x307-3_firmware","vendor":"siemens"},{"product":"scalance_x307-3ld_firmware","vendor":"siemens"},{"product":"scalance_x308-2_firmware","vendor":"siemens"},{"product":"scalance_x308-2ld_firmware","vendor":"siemens"},{"product":"scalance_x308-2lh\\+_firmware","vendor":"siemens"},{"product":"scalance_x308-2lh_firmware","vendor":"siemens"},{"product":"scalance_x308-2m_firmware","vendor":"siemens"},{"product":"scalance_x308-2m_poe_firmware","vendor":"siemens"},{"product":"scalance_x308-2m_ts_firmware","vendor":"siemens"},{"product":"scalance_x310_firmware","vendor":"siemens"},{"product":"scalance_x310fe_firmware","vendor":"siemens"},{"product":"scalance_x320-1-2ldfe_firmware","vendor":"siemens"},{"product":"scalance_x320-1fe_firmware","vendor":"siemens"},{"product":"scalance_x408-2_firmware","vendor":"siemens"},{"product":"scalance_xr324-12m_firmware","vendor":"siemens"},{"product":"scalance_xr324-12m_ts_firmware","vendor":"siemens"},{"product":"scalance_xr324-4m_eec_firmware","vendor":"siemens"},{"product":"scalance_xr324-4m_poe_firmware","vendor":"siemens"},{"product":"scalance_xr324-4m_poe_ts_firmware","vendor":"siemens"},{"product":"siplus_net_scalance_x308-2_firmware","vendor":"siemens"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-352","name":"Cross-Site Request Forgery"}],"description":"A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. The integrated web server of the affected device could allow remote attackers to perform actions with the permissions of a victim user, provided the victim user has an active session and is induced to trigger the malicious request.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site request forgery in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25754","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"csrf","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25755"},"packages":[],"prev":{"headline":"Memory corruption in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25753"},"products":["SCALANCE X302-7 EEC (230V)","SCALANCE X302-7 EEC (230V, coated)","SCALANCE X302-7 EEC (24V)","SCALANCE X302-7 EEC (24V, coated)","SCALANCE X302-7 EEC (2x 230V)","SCALANCE X302-7 EEC (2x 230V, coated)","SCALANCE X302-7 EEC (2x 24V)","SCALANCE X302-7 EEC (2x 24V, coated)","SCALANCE X304-2FE","SCALANCE X306-1LD FE","SCALANCE X307-2 EEC (230V)","SCALANCE X307-2 EEC (230V, coated)","SCALANCE X307-2 EEC (24V)","SCALANCE X307-2 EEC (24V, coated)","SCALANCE X307-2 EEC (2x 230V)","SCALANCE X307-2 EEC (2x 230V, coated)","SCALANCE X307-2 EEC (2x 24V)","SCALANCE X307-2 EEC (2x 24V, coated)","SCALANCE X307-3","SCALANCE X307-3LD","SCALANCE X308-2","SCALANCE X308-2LD","SCALANCE X308-2LH","SCALANCE X308-2LH+","SCALANCE X308-2M","SCALANCE X308-2M PoE","SCALANCE X308-2M TS","SCALANCE X310","SCALANCE X310FE","SCALANCE X320-1 FE","SCALANCE X320-1-2LD FE","SCALANCE X408-2","SCALANCE XR324-12M (230V, ports on front)","SCALANCE XR324-12M (230V, ports on rear)","SCALANCE XR324-12M (24V, ports on front)","SCALANCE XR324-12M (24V, ports on rear)","SCALANCE XR324-12M TS (24V)","SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)","SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)","SCALANCE XR324-4M EEC (24V, ports on front)","SCALANCE XR324-4M EEC (24V, ports on rear)","SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)","SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)","SCALANCE XR324-4M EEC (2x 24V, ports on front)","SCALANCE XR324-4M EEC (2x 24V, ports on rear)","SCALANCE XR324-4M PoE (230V, ports on front)","SCALANCE XR324-4M PoE (230V, ports on rear)","SCALANCE XR324-4M PoE (24V, ports on front)","SCALANCE XR324-4M PoE (24V, ports on rear)","SCALANCE XR324-4M PoE TS (24V, ports on front)","SIPLUS NET SCALANCE X308-2"],"published":"2022-04-12","related":[{"cvss_score":9.8,"headline":"Weak cryptography in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25752","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":8.8,"headline":"Memory corruption in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25753","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.5,"headline":"Other in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25751","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.5,"headline":"Missing authorization in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-25755","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.5,"headline":"Memory corruption in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-26334","kev_date_added":null,"published":"2022-04-12"},{"cvss_score":7.5,"headline":"Memory corruption in SCALANCE X302-7 EEC (230V)","id":"CVE-2022-26335","kev_date_added":null,"published":"2022-04-12"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Siemens"]},"summary":"Cross-site request forgery vulnerability in Siemens SCALANCE switches allows attackers to perform unauthorized actions on behalf of authenticated users.","url":"https://insights.sbomify.com/CVE-2022-25754/"}