{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2022-25780 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-25780 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-25780 is a medium-severity vulnerability in Secomea GateManager, published on 4 May 2022. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-25780 and fix it if it is affected.\n\nWhat it is: CVE-2022-25780 is a medium-severity vulnerability in Secomea GateManager, published on 4 May 2022. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-25780 in the wild and no public exploit code.\n\nAffected product: Secomea GateManager. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-25780/ (Markdown: https://insights.sbomify.com/CVE-2022-25780/index.md)","id":"CVE-2022-25780","markdown":"https://insights.sbomify.com/CVE-2022-25780/index.md","name":"CVE-2022-25780","record":{"aliases":["GHSA-wpqj-cmjr-jpxj"],"analysis":{"component_type":"server_software","fix_type":"patch","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Secomea GateManager","requires_auth":"low_privilege","summary":"A logged-in user can query devices outside their authorized scope, leading to information exposure in Secomea GateManager.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Secomea","cpe":[{"product":"gatemanager_4250_firmware","vendor":"secomea"},{"product":"gatemanager_4260_firmware","vendor":"secomea"},{"product":"gatemanager_8250_firmware","vendor":"secomea"},{"product":"gatemanager_9250_firmware","vendor":"secomea"}],"cvss":{"score":4.3,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-200","name":"Exposure of Sensitive Information to an Unauthorized Actor"}],"description":"Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information leak via device availability query function","id":"CVE-2022-25780","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Reflected XSS issues in GateManager","id":"CVE-2022-25781"},"packages":[],"prev":{"headline":"Insufficient scope checks allows adding unrelated audit log entries","id":"CVE-2022-25779"},"products":["GateManager"],"published":"2022-05-04","related":[{"cvss_score":9,"headline":"Path traversal in GateManager","id":"CVE-2020-29026","kev_date_added":null,"published":"2021-02-15"},{"cvss_score":7.5,"headline":"GTA URLs issued by LMM WEB API may leak information","id":"CVE-2022-25787","kev_date_added":null,"published":"2022-05-04"},{"cvss_score":7.1,"headline":"Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation","id":"CVE-2020-29031","kev_date_added":null,"published":"2021-02-15"},{"cvss_score":5.6,"headline":"Clients may connect to a GateManager with TLS 1.0","id":"CVE-2021-32010","kev_date_added":null,"published":"2022-05-04"},{"cvss_score":5.4,"headline":"Insufficient privilege checks on object access and updates.","id":"CVE-2022-25782","kev_date_added":null,"published":"2022-05-04"},{"cvss_score":5.3,"headline":"Host Header Injection allowing web cache poisoning attacks","id":"CVE-2020-29022","kev_date_added":null,"published":"2021-02-16"},{"cvss_score":5.3,"headline":"Missing HtppOnly and Secure flags","id":"CVE-2020-29024","kev_date_added":null,"published":"2021-02-16"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Secomea"]},"summary":"A logged-in user can query devices outside their authorized scope, leading to information exposure in Secomea GateManager.","url":"https://insights.sbomify.com/CVE-2022-25780/"}