{"answers":{"affected":"","exploited":"There is no known exploitation of CVE-2022-26388 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-26388 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-26388 is a medium-severity vulnerability in Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph, published on 7 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-26388 and fix it if it is affected.\n\nWhat it is: CVE-2022-26388 is a medium-severity vulnerability in Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph, published on 7 Feb 2025. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-26388 in the wild and no public exploit code.\n\nAffected product: Welch Allyn ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-26388/ (Markdown: https://insights.sbomify.com/CVE-2022-26388/index.md)","id":"CVE-2022-26388","markdown":"https://insights.sbomify.com/CVE-2022-26388/index.md","name":"CVE-2022-26388","record":{"aliases":["GHSA-4fpr-4qrv-r2vm"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["security_bypass","account_takeover"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Electrocardiograph device","requires_auth":"none","summary":"Hard-coded passwords in ELI electrocardiograph devices allow attackers to bypass authentication and gain unauthorized access.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[],"cvss":{"score":6.4,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L","version":"3.1"},"cwes":[{"id":"CWE-259","name":"Use of Hard-coded Password"}],"description":"A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: \n\nVersions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:\n\nVersions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Use of Hard-Coded Password Vulnerability in ELI Electrocardiograph Devices","id":"CVE-2022-26388","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2022"},"n_packages":0,"n_references":2,"next":{"headline":"Improper Access Control Vulnerability in ELI Electrocardiograph Devices","id":"CVE-2022-26389"},"packages":[],"prev":{"headline":"Race condition in Firefox","id":"CVE-2022-26387"},"products":["ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph","ELI 250c/BUR 250c Resting Electrocardiograph","ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph","ELI 380 Resting Electrocardiograph"],"published":"2025-02-07","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-07","vendors":["Welch Allyn"]},"summary":"Hard-coded passwords in ELI electrocardiograph devices allow attackers to bypass authentication and gain unauthorized access.","url":"https://insights.sbomify.com/CVE-2022-26388/"}