{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2022-26390 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-26390 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-26390 is a medium-severity vulnerability in Baxter Spectrum Wireless Battery Module (WBM), published on 9 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-26390 and fix it if it is affected.\n\nWhat it is: CVE-2022-26390 is a medium-severity vulnerability in Baxter Spectrum Wireless Battery Module (WBM), published on 9 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-26390 in the wild and no public exploit code.\n\nAffected product: Baxter Spectrum Wireless Battery Module (WBM). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-26390/ (Markdown: https://insights.sbomify.com/CVE-2022-26390/index.md)","id":"CVE-2022-26390","markdown":"https://insights.sbomify.com/CVE-2022-26390/index.md","name":"CVE-2022-26390","record":{"aliases":["GHSA-8rq7-p3vq-fh83"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Medical device module","requires_auth":"none","summary":"An attacker with physical access can extract unencrypted network credentials and PHI from the device's internal storage.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[{"product":"baxter_spectrum_iq_35700bax3_firmware","vendor":"baxter"},{"product":"sigma_spectrum_35700bax2_firmware","vendor":"baxter"},{"product":"sigma_spectrum_35700bax_firmware","vendor":"baxter"},{"product":"spectrum_wireless_battery_module_firmware","vendor":"baxter"}],"cvss":{"score":4.2,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-312","name":"Cleartext Storage of Sensitive Information"},{"id":"CWE-311","name":"Missing Encryption of Sensitive Data"}],"description":"The Baxter Spectrum Wireless Battery Module (WBM) stores network credentials and PHI (only applicable to Spectrum IQ pumps using auto programming) in unencrypted form. An attacker with physical access to a device that hasn't had all data and settings erased may be able to extract sensitive information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unencrypted internal storage of security credentials","id":"CVE-2022-26390","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Format String vulnerability","id":"CVE-2022-26392"},"packages":[],"prev":{"headline":"Improper Access Control Vulnerability in ELI Electrocardiograph Devices","id":"CVE-2022-26389"},"products":["Baxter Spectrum Wireless Battery Module (WBM)"],"published":"2022-09-09","related":[{"cvss_score":5.5,"headline":"Unauthenticated network reconfiguration via TCP/UDP","id":"CVE-2022-26394","kev_date_added":null,"published":"2022-09-09"},{"cvss_score":5,"headline":"Format String vulnerability","id":"CVE-2022-26393","kev_date_added":null,"published":"2022-09-09"},{"cvss_score":3.1,"headline":"Format String vulnerability","id":"CVE-2022-26392","kev_date_added":null,"published":"2022-09-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Baxter"]},"summary":"An attacker with physical access can extract unencrypted network credentials and PHI from the device's internal storage.","url":"https://insights.sbomify.com/CVE-2022-26390/"}