{"answers":{"affected":"It affects 4 products.","exploited":"There is no known exploitation of CVE-2022-26394 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-26394 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-26394 is a medium-severity missing authorization vulnerability in Baxter Spectrum Wireless Battery Module (WBM), published on 9 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-26394 and fix it if it is affected.\n\nWhat it is: CVE-2022-26394 is a medium-severity missing authorization vulnerability in Baxter Spectrum Wireless Battery Module (WBM), published on 9 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-26394 in the wild and no public exploit code.\n\nAffected product: Baxter Spectrum Wireless Battery Module (WBM). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-26394/ (Markdown: https://insights.sbomify.com/CVE-2022-26394/index.md)","id":"CVE-2022-26394","markdown":"https://insights.sbomify.com/CVE-2022-26394/index.md","name":"CVE-2022-26394","record":{"aliases":["GHSA-cf6p-6fqm-mpw5"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["denial_of_service","security_bypass"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Baxter Spectrum WBM","requires_auth":"low_privilege","summary":"An attacker can perform a man-in-the-middle attack to modify network parameters and cause connection failures due to lack of mutual authentication.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Baxter","cpe":[{"product":"baxter_spectrum_iq_35700bax3_firmware","vendor":"baxter"},{"product":"sigma_spectrum_35700bax2_firmware","vendor":"baxter"},{"product":"sigma_spectrum_35700bax_firmware","vendor":"baxter"},{"product":"spectrum_wireless_battery_module_firmware","vendor":"baxter"}],"cvss":{"score":5.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"}],"description":"The Baxter Spectrum WBM does not perform mutual authentication with the gateway server host. This may allow an attacker to perform a man in the middle attack that modifies parameters making the network connection fail.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unauthenticated network reconfiguration via TCP/UDP","id":"CVE-2022-26394","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Command injection in VMG3312-T20A firmware","id":"CVE-2022-26413"},"packages":[],"prev":{"headline":"Format String vulnerability","id":"CVE-2022-26393"},"products":["Baxter Spectrum Wireless Battery Module (WBM)"],"published":"2022-09-09","related":[{"cvss_score":5,"headline":"Format String vulnerability","id":"CVE-2022-26393","kev_date_added":null,"published":"2022-09-09"},{"cvss_score":4.2,"headline":"Unencrypted internal storage of security credentials","id":"CVE-2022-26390","kev_date_added":null,"published":"2022-09-09"},{"cvss_score":3.1,"headline":"Format String vulnerability","id":"CVE-2022-26392","kev_date_added":null,"published":"2022-09-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-16","vendors":["Baxter"]},"summary":"An attacker can perform a man-in-the-middle attack to modify network parameters and cause connection failures due to lack of mutual authentication.","url":"https://insights.sbomify.com/CVE-2022-26394/"}