{"answers":{"affected":"It affects 3 products.","exploited":"There is no known exploitation of CVE-2022-26476 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-26476 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-26476 is a high-severity vulnerability in Siemens Spectrum Power 4, published on 14 Jun 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-26476 and fix it if it is affected.\n\nWhat it is: CVE-2022-26476 is a high-severity vulnerability in Siemens Spectrum Power 4, published on 14 Jun 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-26476 in the wild and no public exploit code.\n\nAffected product: Siemens Spectrum Power 4. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-26476/ (Markdown: https://insights.sbomify.com/CVE-2022-26476/index.md)","id":"CVE-2022-26476","markdown":"https://insights.sbomify.com/CVE-2022-26476/index.md","name":"CVE-2022-26476","record":{"aliases":["GHSA-wx4w-rcpp-p5wm"],"analysis":{"component_type":"ics_ot","fix_type":"configuration_change","impacts":["privilege_escalation","data_read"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Siemens Spectrum Power","requires_auth":"none","summary":"An unauthenticated attacker can log in using default credentials to gain administrative access to the Shared HIS component in Siemens Spectrum Power systems.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"spectrum_power_4","vendor":"siemens"},{"product":"spectrum_power_7","vendor":"siemens"},{"product":"spectrum_power_microgrid_management_system","vendor":"siemens"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"}],"description":"A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Spectrum Power 4","id":"CVE-2022-26476","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Denial of service in readExternal method","id":"CVE-2022-26477"},"packages":[],"prev":{"headline":"Memory corruption in MT6761, MT6762, MT6765, MT6768, MT6769, MT6779, MT6781, MT6785, MT6789, MT6853, MT6855, MT6873, MT6875, MT6879, MT6883, MT6885, MT6889, MT6895, MT6983, MT7663, MT7902, MT7921, MT8167S, MT8175, MT8183, MT8185, MT8362A, MT8365, MT8385, MT8512A, MT8518, MT8532, MT8667, MT8695, MT8696, MT8766, MT8768, MT8786, MT8788, MT8789","id":"CVE-2022-26475"},"products":["Spectrum Power 4","Spectrum Power 7","Spectrum Power MGMS"],"published":"2022-06-14","related":[{"cvss_score":9.8,"headline":"Command injection in Spectrum Power™ 4","id":"CVE-2019-6579","kev_date_added":null,"published":"2019-04-17"},{"cvss_score":6.1,"headline":"Cross-site scripting in Spectrum Power 4","id":"CVE-2022-23312","kev_date_added":null,"published":"2022-02-09"},{"cvss_score":5.3,"headline":"Information disclosure in Spectrum Power 4","id":"CVE-2020-15784","kev_date_added":null,"published":"2020-09-09"},{"cvss_score":5.3,"headline":"Information disclosure in Spectrum Power 4","id":"CVE-2020-15790","kev_date_added":null,"published":"2020-09-09"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Siemens"]},"summary":"An unauthenticated attacker can log in using default credentials to gain administrative access to the Shared HIS component in Siemens Spectrum Power systems.","url":"https://insights.sbomify.com/CVE-2022-26476/"}