{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-2660 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-2660 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-2660 is a critical vulnerability in Delta Electronics Industrial Automation DIALink, published on 13 Dec 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-2660 and fix it if it is affected.\n\nWhat it is: CVE-2022-2660 is a critical vulnerability in Delta Electronics Industrial Automation DIALink, published on 13 Dec 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-2660 in the wild and no public exploit code.\n\nAffected product: Delta Electronics Industrial Automation DIALink. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-2660/ (Markdown: https://insights.sbomify.com/CVE-2022-2660/index.md)","id":"CVE-2022-2660","markdown":"https://insights.sbomify.com/CVE-2022-2660/index.md","name":"CVE-2022-2660","record":{"aliases":["GHSA-cx6m-hwfj-fvvw"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial Automation DIALink","requires_auth":"none","summary":"Attackers can decrypt sensitive data and compromise machines using a hard-coded cryptographic key in Delta Industrial Automation DIALink.","user_interaction":"not_required","vuln_class":"hardcoded_credentials"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"dialink","vendor":"deltaww"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-798","name":"Use of Hard-coded Credentials"},{"id":"CWE-321","name":"Use of Hard-coded Cryptographic Key"}],"description":"Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Hardcoded credentials in Industrial Automation DIALink","id":"CVE-2022-2660","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"hardcoded_credentials","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Sequi PortBloque S Improper Authorization","id":"CVE-2022-2661"},"packages":[],"prev":{"headline":"WP Spell Check \u003c 9.13 - Admin+ Stored Cross-Site Scripting","id":"CVE-2022-2658"},"products":["Industrial Automation DIALink"],"published":"2022-12-13","related":[{"cvss_score":10,"headline":"DIALink - Directory Traversal Authentication Bypass Vulnerability","id":"CVE-2025-58321","kev_date_added":null,"published":"2025-09-11"},{"cvss_score":8.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38418","kev_date_added":null,"published":"2021-11-03"},{"cvss_score":8.1,"headline":"ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal","id":"CVE-2022-2969","kev_date_added":null,"published":"2022-12-01"},{"cvss_score":7.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38416","kev_date_added":null,"published":"2021-11-03"},{"cvss_score":7.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38420","kev_date_added":null,"published":"2021-11-03"},{"cvss_score":7.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38422","kev_date_added":null,"published":"2021-11-03"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Delta Electronics"]},"summary":"Attackers can decrypt sensitive data and compromise machines using a hard-coded cryptographic key in Delta Industrial Automation DIALink.","url":"https://insights.sbomify.com/CVE-2022-2660/"}