{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-28374 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-28374 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-28374 is a high-severity command injection vulnerability in n/a, published on 14 Jul 2022. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-28374 and fix it if it is affected.\n\nWhat it is: CVE-2022-28374 is a high-severity command injection vulnerability in n/a, published on 14 Jul 2022. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-28374 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-28374/ (Markdown: https://insights.sbomify.com/CVE-2022-28374/index.md)","id":"CVE-2022-28374","markdown":"https://insights.sbomify.com/CVE-2022-28374/index.md","name":"CVE-2022-28374","record":{"aliases":["GHSA-45v5-583j-cjfj"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"5G Home Outdoor Unit","requires_auth":"low_privilege","summary":"Authenticated attackers on the local network can inject shell commands into the Engineering portal to execute arbitrary code as root on the Verizon 5G Home Outdoor Unit.","user_interaction":"not_required","vuln_class":"command_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"lvskihp_outdoorunit_firmware","vendor":"verizon"}],"cvss":{"score":8.8,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-78","name":"Improper Neutralization of Special Elements used in an OS Command"}],"description":"Verizon 5G Home LVSKIHP OutDoorUnit (ODU) 3.33.101.0 does not property sanitize user-controlled parameters within the DMACC URLs on the Settings page of the Engineering portal. An authenticated remote attacker on the local network can inject shell metacharacters into /usr/lib/lua/5.1/luci/controller/admin/settings.lua to achieve remote code execution as root.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Command injection in n/a","id":"CVE-2022-28374","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"command_injection","year":"2022"},"n_packages":0,"n_references":2,"next":{"headline":"Command injection in n/a","id":"CVE-2022-28375"},"packages":[],"prev":{"headline":"Command injection in n/a","id":"CVE-2022-28373"},"products":["n/a"],"published":"2022-07-14","related":[{"cvss_score":9.8,"headline":"Command injection in n/a","id":"CVE-2022-28375","kev_date_added":null,"published":"2022-07-14"},{"cvss_score":7.5,"headline":"Code injection in n/a","id":"CVE-2022-28370","kev_date_added":null,"published":"2022-07-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Authenticated attackers on the local network can inject shell commands into the Engineering portal to execute arbitrary code as root on the Verizon 5G Home Outdoor Unit.","url":"https://insights.sbomify.com/CVE-2022-28374/"}