CVE-2022-28618 Command injection in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
Attackers can execute arbitrary commands on HPE Nimble Storage appliances, requiring a software upgrade to mitigate.
- Exploited in the wild
- Not known
- Login needed
- Not needed
- Attackable
- Over the internet
- Victim action needed
- Not needed
- Fix
- None listed
What is CVE-2022-28618?
CVE-2022-28618 is a critical command injection vulnerability in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays, published on 20 May 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.
Official description
A command injection security vulnerability has been identified in HPE Nimble Storage Hybrid Flash Arrays, HPE Nimble Storage All Flash Arrays and HPE Nimble Storage Secondary Flash Arrays that could allow an attacker to execute arbitrary commands on a Nimble appliance. HPE has made the following software updates to resolve the vulnerability in HPE Nimble Storage: 5.0.10.100 or later, 5.2.1.0 or later, 6.0.0.100 or later.
Weakness: CWE-77
Which versions are affected by CVE-2022-28618?
It affects 1 product.
Products include Hpe Nimbleos.
How do I fix CVE-2022-28618?
No fix has been published for CVE-2022-28618 yet. Limit exposure of the affected software until one is available.
Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.
Is CVE-2022-28618 being exploited?
There is no known exploitation of CVE-2022-28618 in the wild and no public exploit code.
Other vulnerabilities in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
- CVE-2019-11996 Privilege escalation in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
- CVE-2020-7138 Privilege escalation in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
- CVE-2020-7139 Information disclosure in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
- CVE-2022-23705 File upload in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
- CVE-2022-23703 Other in HPE Nimble Storage Hybrid Flash Arrays; Nimble Storage All Flash Arrays; Nimble Storage Secondary Flash Arrays
Sources
Also known as GHSA-xvr4-pc95-4727.