{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-2969 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-2969 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-2969 is a high-severity path traversal vulnerability in Delta Industrial Automation DIALink, published on 1 Dec 2022. Any signed-in user can exploit it over the network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-2969 and fix it if it is affected.\n\nWhat it is: CVE-2022-2969 is a high-severity path traversal vulnerability in Delta Industrial Automation DIALink, published on 1 Dec 2022. Any signed-in user can exploit it over the network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-2969 in the wild and no public exploit code.\n\nAffected product: Delta Industrial Automation DIALink. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-2969/ (Markdown: https://insights.sbomify.com/CVE-2022-2969/index.md)","id":"CVE-2022-2969","markdown":"https://insights.sbomify.com/CVE-2022-2969/index.md","name":"CVE-2022-2969","record":{"aliases":["GHSA-c28m-8g89-fpm5"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["data_read","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Delta DIALink","requires_auth":"low_privilege","summary":"Attackers can exploit path traversal in Delta DIALink to access or modify files outside the restricted directory, impacting industrial automation systems.","user_interaction":"not_required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"dialink","vendor":"deltaww"}],"cvss":{"score":8.1,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-22","name":"Improper Limitation of a Pathname to a Restricted Directory"}],"description":"Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"ICSA-22-307-03 Delta Industrial Automation DIALink Path traversal","id":"CVE-2022-2969","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"MZ Automation libIEC61850 Stack-Based Buffer Overflow","id":"CVE-2022-2970"},"packages":[],"prev":{"headline":"Information disclosure in UA Modbus Server","id":"CVE-2022-2967"},"products":["DIALink"],"published":"2022-12-01","related":[{"cvss_score":10,"headline":"DIALink - Directory Traversal Authentication Bypass Vulnerability","id":"CVE-2025-58321","kev_date_added":null,"published":"2025-09-11"},{"cvss_score":9.8,"headline":"Hardcoded credentials in Industrial Automation DIALink","id":"CVE-2022-2660","kev_date_added":null,"published":"2022-12-13"},{"cvss_score":8.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38418","kev_date_added":null,"published":"2021-11-03"},{"cvss_score":7.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38416","kev_date_added":null,"published":"2021-11-03"},{"cvss_score":7.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38420","kev_date_added":null,"published":"2021-11-03"},{"cvss_score":7.8,"headline":"Delta Electronics DIALink","id":"CVE-2021-38422","kev_date_added":null,"published":"2021-11-03"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Delta Industrial Automation"]},"summary":"Attackers can exploit path traversal in Delta DIALink to access or modify files outside the restricted directory, impacting industrial automation systems.","url":"https://insights.sbomify.com/CVE-2022-2969/"}