{"answers":{"affected":"It affects 18 products.","exploited":"There is no known exploitation of CVE-2022-29875 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-29875 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-29875 is a critical unsafe deserialization vulnerability in Siemens Biograph Horizon PET/CT Systems, published on 1 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-29875 and fix it if it is affected.\n\nWhat it is: CVE-2022-29875 is a critical unsafe deserialization vulnerability in Siemens Biograph Horizon PET/CT Systems, published on 1 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-29875 in the wild and no public exploit code.\n\nAffected product: Siemens Biograph Horizon PET/CT Systems. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-29875/ (Markdown: https://insights.sbomify.com/CVE-2022-29875/index.md)","id":"CVE-2022-29875","markdown":"https://insights.sbomify.com/CVE-2022-29875/index.md","name":"CVE-2022-29875","record":{"aliases":["GHSA-qq72-778q-mwmx"],"analysis":{"component_type":"iot_embedded","fix_type":"patch","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens medical imaging","requires_auth":"none","summary":"Unauthenticated attackers can execute arbitrary code on Siemens medical imaging systems via unsafe deserialization if specific TCP ports are reachable.","user_interaction":"not_required","vuln_class":"deserialization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"biograph_horizon_pet\\/ct_systems_firmware","vendor":"siemens"},{"product":"magnetom_numaris_x_firmware","vendor":"siemens"},{"product":"mammomat_revelation_firmware","vendor":"siemens"},{"product":"naeotom_alpha_firmware","vendor":"siemens"},{"product":"somatom_go.all_firmware","vendor":"siemens"},{"product":"somatom_go.now_firmware","vendor":"siemens"},{"product":"somatom_go.open_pro_firmware","vendor":"siemens"},{"product":"somatom_go.sim_firmware","vendor":"siemens"},{"product":"somatom_go.up_firmware","vendor":"siemens"},{"product":"somatom_x.cite_firmware","vendor":"siemens"},{"product":"somatom_x.creed_firmware","vendor":"siemens"},{"product":"symbia.net","vendor":"siemens"},{"product":"symbia_e_firmware","vendor":"siemens"},{"product":"symbia_evo_firmware","vendor":"siemens"},{"product":"symbia_intevo_firmware","vendor":"siemens"},{"product":"symbia_s_firmware","vendor":"siemens"},{"product":"symbia_t_firmware","vendor":"siemens"},{"product":"syngo.via","vendor":"siemens"}],"cvss":{"score":9.8,"severity":"critical","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-502","name":"Deserialization of Untrusted Data"}],"description":"A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions \u003c VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions \u003c VC20D), NAEOTOM Alpha (All VA40 versions \u003c VA40 SP2), SOMATOM X.cite (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions \u003c VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions \u003c VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions \u003c VB22A-UD03), Symbia Evo (All VB22 versions \u003c VB22A-UD03), Symbia Intevo (All VB22 versions \u003c VB22A-UD03), Symbia T (All VB22 versions \u003c VB22A-UD03), Symbia.net (All VB22 versions \u003c VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions \u003c VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions \u003c VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Deserialization in Biograph Horizon PET/CT Systems","id":"CVE-2022-29875","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"deserialization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site scripting in SICAM T","id":"CVE-2022-29876"},"packages":[],"prev":{"headline":"Information disclosure in SICAM T","id":"CVE-2022-29874"},"products":["Biograph Horizon PET/CT Systems","MAGNETOM Family","MAMMOMAT Revelation","NAEOTOM Alpha","SOMATOM X.cite","SOMATOM X.creed","SOMATOM go.All","SOMATOM go.Now","SOMATOM go.Open Pro","SOMATOM go.Sim","SOMATOM go.Top","SOMATOM go.Up","Symbia E/S","Symbia Evo","Symbia Intevo","Symbia T","Symbia.net","syngo.via VB10","syngo.via VB20","syngo.via VB30","syngo.via VB40","syngo.via VB50","syngo.via VB60"],"published":"2022-06-01","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Siemens"]},"summary":"Unauthenticated attackers can execute arbitrary code on Siemens medical imaging systems via unsafe deserialization if specific TCP ports are reachable.","url":"https://insights.sbomify.com/CVE-2022-29875/"}