{"answers":{"affected":"It affects 36 products.","exploited":"There is no known exploitation of CVE-2022-29880 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-29880 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-29880 is a medium-severity cross-site scripting vulnerability in Siemens SICAM T, published on 10 May 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-29880 and fix it if it is affected.\n\nWhat it is: CVE-2022-29880 is a medium-severity cross-site scripting vulnerability in Siemens SICAM T, published on 10 May 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-29880 in the wild and no public exploit code.\n\nAffected product: Siemens SICAM T. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-29880/ (Markdown: https://insights.sbomify.com/CVE-2022-29880/index.md)","id":"CVE-2022-29880","markdown":"https://insights.sbomify.com/CVE-2022-29880/index.md","name":"CVE-2022-29880","record":{"aliases":["GHSA-xf7c-hpj8-f7wx"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["account_takeover","data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"SICAM T device","requires_auth":"low_privilege","summary":"An authenticated attacker can inject persistent XSS payloads into the SICAM T configuration interface to execute arbitrary actions as a logged-in user.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kg8500-0aa00-0aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa00-2aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa10-0aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa10-2aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa30-0aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa30-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa01-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa01-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa02-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa02-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa11-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa11-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa12-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa12-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa31-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa31-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa32-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa32-2aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa00-0aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa00-2aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa10-0aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa10-2aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa30-0aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa30-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa01-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa01-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa02-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa02-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa11-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa11-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa12-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa12-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa31-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa31-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa32-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa32-2aa0_firmware","vendor":"siemens"}],"cvss":{"score":6.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"A vulnerability has been identified in SICAM T (All versions \u003c V3.0). Affected devices do not properly validate input in the configuration interface. This could allow an authenticated attacker to place persistent XSS attacks to perform arbitrary actions in the name of a logged user which accesses the affected views.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in SICAM T","id":"CVE-2022-29880","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Missing authorization in SICAM T","id":"CVE-2022-29881"},"packages":[],"prev":{"headline":"Missing authorization in SICAM T","id":"CVE-2022-29879"},"products":["SICAM T"],"published":"2022-05-10","related":[{"cvss_score":9.8,"headline":"A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions","id":"CVE-2022-41665","kev_date_added":null,"published":"2022-10-11"},{"cvss_score":9.3,"headline":"Other in SICAM T","id":"CVE-2022-29873","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":8.8,"headline":"Information disclosure in SICAM T","id":"CVE-2022-29874","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":8.7,"headline":"Other in SICAM T","id":"CVE-2022-29872","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":7.5,"headline":"Auth bypass in SICAM P850","id":"CVE-2022-40226","kev_date_added":null,"published":"2022-10-11"},{"cvss_score":7.5,"headline":"Auth bypass in SICAM T","id":"CVE-2022-29878","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":7.1,"headline":"Cross-site scripting in SICAM T","id":"CVE-2022-29876","kev_date_added":null,"published":"2022-05-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-12-09","vendors":["Siemens"]},"summary":"An authenticated attacker can inject persistent XSS payloads into the SICAM T configuration interface to execute arbitrary actions as a logged-in user.","url":"https://insights.sbomify.com/CVE-2022-29880/"}