{"answers":{"affected":"It affects 36 products.","exploited":"There is no known exploitation of CVE-2022-29883 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-29883 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-29883 is a medium-severity missing authorization vulnerability in Siemens SICAM T, published on 10 May 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-29883 and fix it if it is affected.\n\nWhat it is: CVE-2022-29883 is a medium-severity missing authorization vulnerability in Siemens SICAM T, published on 10 May 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-29883 in the wild and no public exploit code.\n\nAffected product: Siemens SICAM T. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-29883/ (Markdown: https://insights.sbomify.com/CVE-2022-29883/index.md)","id":"CVE-2022-29883","markdown":"https://insights.sbomify.com/CVE-2022-29883/index.md","name":"CVE-2022-29883","record":{"aliases":["GHSA-76j9-qghq-rx67"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_modify"],"network_reachable":"yes","non_default_config":false,"product_category":"Siemens SICAM T","requires_auth":"none","summary":"Unauthenticated attackers can delete log files on Siemens SICAM T devices due to missing access restrictions on web interface pages.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"siemens","cpe":[{"product":"7kg8500-0aa00-0aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa00-2aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa10-0aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa10-2aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa30-0aa0_firmware","vendor":"siemens"},{"product":"7kg8500-0aa30-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa01-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa01-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa02-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa02-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa11-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa11-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa12-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa12-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa31-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa31-2aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa32-0aa0_firmware","vendor":"siemens"},{"product":"7kg8501-0aa32-2aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa00-0aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa00-2aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa10-0aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa10-2aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa30-0aa0_firmware","vendor":"siemens"},{"product":"7kg8550-0aa30-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa01-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa01-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa02-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa02-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa11-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa11-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa12-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa12-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa31-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa31-2aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa32-0aa0_firmware","vendor":"siemens"},{"product":"7kg8551-0aa32-2aa0_firmware","vendor":"siemens"}],"cvss":{"score":6.9,"severity":"medium","source":"cna","vector":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N","version":"4.0"},"cwes":[{"id":"CWE-306","name":"Missing Authentication for Critical Functionality"},{"id":"CWE-287","name":"Improper Authentication"}],"description":"A vulnerability has been identified in SICAM T (All versions \u003c V3.0). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Missing authorization in SICAM T","id":"CVE-2022-29883","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Denial of service in CP-8000 MASTER MODULE WITH I/O -25/+70°C","id":"CVE-2022-29884"},"packages":[],"prev":{"headline":"Cross-site scripting in SICAM T","id":"CVE-2022-29882"},"products":["SICAM T"],"published":"2022-05-10","related":[{"cvss_score":9.8,"headline":"A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions \u003c V3.10), SICAM P850 (7KG8500-0AA00-2AA0) (All versions","id":"CVE-2022-41665","kev_date_added":null,"published":"2022-10-11"},{"cvss_score":9.3,"headline":"Other in SICAM T","id":"CVE-2022-29873","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":8.8,"headline":"Information disclosure in SICAM T","id":"CVE-2022-29874","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":8.7,"headline":"Other in SICAM T","id":"CVE-2022-29872","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":7.5,"headline":"Auth bypass in SICAM P850","id":"CVE-2022-40226","kev_date_added":null,"published":"2022-10-11"},{"cvss_score":7.5,"headline":"Auth bypass in SICAM T","id":"CVE-2022-29878","kev_date_added":null,"published":"2022-05-10"},{"cvss_score":7.1,"headline":"Cross-site scripting in SICAM T","id":"CVE-2022-29876","kev_date_added":null,"published":"2022-05-10"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2025-12-09","vendors":["Siemens"]},"summary":"Unauthenticated attackers can delete log files on Siemens SICAM T devices due to missing access restrictions on web interface pages.","url":"https://insights.sbomify.com/CVE-2022-29883/"}