CVE-2022-29952 Missing authorization in n/a

Critical 9.1 Published Updated

Attackers can access configuration and historical data via unauthenticated TDI protocols on Bently Nevada condition monitoring equipment.

Exploited in the wild
Not known
Login needed
Not needed
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2022-29952?

CVE-2022-29952 is a critical missing authorization vulnerability in n/a, published on 26 Jul 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.

Official description

Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.

Weakness: CWE-306

Which versions are affected by CVE-2022-29952?

It affects 4 products.

Products include Bakerhughes Bently Nevada 3701\/40 Firmware, Bakerhughes Bently Nevada 3701\/44 Firmware, Bakerhughes Bently Nevada 3701\/46 Firmware, Bakerhughes Bently Nevada 60m100 Firmware.

How do I fix CVE-2022-29952?

No fix has been published for CVE-2022-29952 yet. Limit exposure of the affected software until one is available.

Upgrade, and check permissions on every request on the server, not only in the interface. More about Missing authorization.

Is CVE-2022-29952 being exploited?

There is no known exploitation of CVE-2022-29952 in the wild and no public exploit code.

Sources

Also known as GHSA-xgjg-q85m-vvmx.

Is CVE-2022-29952 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free