{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-3007 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-3007 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-3007 is a high-severity missing authorization vulnerability in Syska SW100 Smartwatch, published on 31 Oct 2023. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-3007 and fix it if it is affected.\n\nWhat it is: CVE-2022-3007 is a high-severity missing authorization vulnerability in Syska SW100 Smartwatch, published on 31 Oct 2023. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-3007 in the wild and no public exploit code.\n\nAffected product: Syska SW100 Smartwatch. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-3007/ (Markdown: https://insights.sbomify.com/CVE-2022-3007/index.md)","id":"CVE-2022-3007","markdown":"https://insights.sbomify.com/CVE-2022-3007/index.md","name":"CVE-2022-3007","record":{"aliases":["GHSA-7247-9948-8r7q"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","data_modify"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Smartwatch","requires_auth":"none","summary":"An unauthenticated attacker can exploit improper DFU configuration to perform firmware updates, reboot, or manipulate data on the smartwatch.","user_interaction":"not_required","vuln_class":"missing_authorization"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERT-In","cpe":[{"product":"sw100_smartwatch_firmware","vendor":"syska"}],"cvss":{"score":8.1,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-862","name":"Missing Authorization"}],"description":"The vulnerability exists in Syska SW100 Smartwatch due to an improper implementation and/or configuration of Nordic Device Firmware Update (DFU) which is used for performing Over-The-Air (OTA) firmware updates on the Bluetooth Low Energy (BLE) devices. An unauthenticated attacker could exploit this vulnerability by setting arbitrary values to handle on the vulnerable device over Bluetooth.\n\nSuccessful exploitation of this vulnerability could allow the attacker to perform firmware update, device reboot or data manipulation on the target device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Unauthorized Access Vulnerability in Syska SW100 Smartwatch","id":"CVE-2022-3007","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"missing_authorization","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Command Injection on tinygltf","id":"CVE-2022-3008"},"packages":[],"prev":{"headline":"Cross-site Scripting (XSS) - Stored in yetiforcecompany/yetiforcecrm","id":"CVE-2022-3005"},"products":["Syska SW100 Smartwatch"],"published":"2023-10-31","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Syska Led Lights Pvt Ltd"]},"summary":"An unauthenticated attacker can exploit improper DFU configuration to perform firmware updates, reboot, or manipulate data on the smartwatch.","url":"https://insights.sbomify.com/CVE-2022-3007/"}