{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-30232 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-30232 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-30232 is a high-severity vulnerability in Schneider Electric Power Logic ION Setup, published on 2 Jun 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-30232 and fix it if it is affected.\n\nWhat it is: CVE-2022-30232 is a high-severity vulnerability in Schneider Electric Power Logic ION Setup, published on 2 Jun 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-30232 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Power Logic ION Setup. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-30232/ (Markdown: https://insights.sbomify.com/CVE-2022-30232/index.md)","id":"CVE-2022-30232","markdown":"https://insights.sbomify.com/CVE-2022-30232/index.md","name":"CVE-2022-30232","record":{"aliases":["GHSA-2x38-7mv7-h86v"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":true,"product_category":"Power Logic ION Setup","requires_auth":"low_privilege","summary":"Improper input validation allows remote code execution if an attacker intercepts network traffic or has configuration access to the device.","user_interaction":"required","vuln_class":"other"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"powerlogic_ion_setup_firmware","vendor":"schneider-electric"}],"cvss":{"score":8,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"A CWE-20: Improper Input Validation vulnerability exists that could cause potential remote code execution when an attacker is able to intercept and modify a request on the same network or has configuration access to an ION device on the network. Affected Products: Wiser Smart, EER21000 \u0026 EER21001 (V4.5 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Other in Power Logic ION Setup","id":"CVE-2022-30232","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"other","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Other in Wiser Smart","id":"CVE-2022-30233"},"packages":[],"prev":{"headline":"Information disclosure in SICAM GridEdge (Classic)","id":"CVE-2022-30231"},"products":["Power Logic ION Setup"],"published":"2022-06-02","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Schneider Electric"]},"summary":"Improper input validation allows remote code execution if an attacker intercepts network traffic or has configuration access to the device.","url":"https://insights.sbomify.com/CVE-2022-30232/"}