{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-3027 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-3027 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-3027 is a medium-severity path traversal vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-3027 and fix it if it is affected.\n\nWhat it is: CVE-2022-3027 is a medium-severity path traversal vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-3027 in the wild and no public exploit code.\n\nAffected product: CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-3027/ (Markdown: https://insights.sbomify.com/CVE-2022-3027/index.md)","id":"CVE-2022-3027","markdown":"https://insights.sbomify.com/CVE-2022-3027/index.md","name":"CVE-2022-3027","record":{"aliases":["GHSA-q7x7-x9qf-5p7c"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["data_modify","other"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Patient monitor","requires_auth":"none","summary":"An attacker can exploit unsanitized Wi-Fi SSID names to write arbitrary files or display incorrect information on Contec Health CMS8000 patient monitors.","user_interaction":"required","vuln_class":"path_traversal"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cms8000_firmware","vendor":"contechealth"}],"cvss":{"score":5.7,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Contec Health CMS8000","id":"CVE-2022-3027","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"path_traversal","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Race condition in Linux kernel","id":"CVE-2022-3028"},"packages":[],"prev":{"headline":"WP Users Exporter \u003c= 1.4.2 - CSV Injection","id":"CVE-2022-3026"},"products":["CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor"],"published":"2022-09-13","related":[{"cvss_score":7.5,"headline":"Contec Health CMS8000","id":"CVE-2022-38100","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":6.8,"headline":"Contec Health CMS8000","id":"CVE-2022-36385","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":4.3,"headline":"Contec Health CMS8000","id":"CVE-2022-38069","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":3,"headline":"Contec Health CMS8000","id":"CVE-2022-38453","kev_date_added":null,"published":"2022-09-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Contec Health"]},"summary":"An attacker can exploit unsanitized Wi-Fi SSID names to write arbitrary files or display incorrect information on Contec Health CMS8000 patient monitors.","url":"https://insights.sbomify.com/CVE-2022-3027/"}