CVE-2022-30620 Cellinx NVT – IP PTZ Camera Privilege Escalation

High 8.2 Published Updated

An attacker can escalate privileges to administrator by modifying specific cookie values in Cellinx IP PTZ Cameras with guest access enabled.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
A user has to click or open something
Fix
None listed

What is CVE-2022-30620?

CVE-2022-30620 is a high-severity vulnerability in Cellinx NVT - IP PTZ Camera, published on 18 Jul 2022. Any signed-in user can exploit it over the network, and only if a user opens a file or follows a link.

Official description

On Cellinx Camera with guest enabled, attacker with web access can elevate privileges to administrative: "1" to "0" privileges by changing the following cookie values from "is_admin", "showConfig". Administrative Privileges which allows changing various configuration in the camera.

Weakness: CWE-565

Which versions are affected by CVE-2022-30620?

It affects 1 product.

Products include Cellinx Cellinx Nvt - Ip Ptz Camera Firmware.

How do I fix CVE-2022-30620?

No fix has been published for CVE-2022-30620 yet. Limit exposure of the affected software until one is available.

Is CVE-2022-30620 being exploited?

There is no known exploitation of CVE-2022-30620 in the wild and no public exploit code.

Sources

Also known as GHSA-7mq3-jhxf-cfj7.

Is CVE-2022-30620 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.