{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-31790 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-31790 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-31790 is a high-severity vulnerability in Watchguard Fireware, published on 6 Sep 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-31790 and fix it if it is affected.\n\nWhat it is: CVE-2022-31790 is a high-severity vulnerability in Watchguard Fireware, published on 6 Sep 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-31790 in the wild and no public exploit code.\n\nAffected product: Watchguard Fireware. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-31790/ (Markdown: https://insights.sbomify.com/CVE-2022-31790/index.md)","id":"CVE-2022-31790","markdown":"https://insights.sbomify.com/CVE-2022-31790/index.md","name":"CVE-2022-31790","record":{"aliases":["GHSA-j534-3ccm-843p"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read"],"network_reachable":"yes","non_default_config":false,"product_category":"Firebox and XTM appliances","requires_auth":"none","summary":"Unauthenticated attackers can retrieve sensitive authentication server settings from WatchGuard Firebox and XTM appliances via malicious requests to exposed endpoints.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"fireware","vendor":"watchguard"}],"cvss":{"score":7.5,"severity":"high","source":"nvd","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"cwes":[],"description":"WatchGuard Firebox and XTM appliances allow an unauthenticated remote attacker to retrieve sensitive authentication server settings by sending a malicious request to exposed authentication endpoints. This is fixed in Fireware OS 12.8.1, 12.5.10, and 12.1.4.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2022-31790","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":"watchguard:fireware","products":["watchguard:fireware"],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Privilege escalation in n/a","id":"CVE-2022-31791"},"packages":[],"prev":{"headline":"Integer overflow in n/a","id":"CVE-2022-31789"},"products":["n/a"],"published":"2022-09-06","related":[{"cvss_score":9.8,"headline":"WatchGuard Firebox and XTM Appliances Arbitrary Code Execution","id":"CVE-2022-26318","kev_date_added":"2022-03-25","published":"2022-03-04"},{"cvss_score":9.3,"headline":"WatchGuard Firebox Out of Bounds Write","id":"CVE-2025-14733","kev_date_added":"2025-12-19","published":"2025-12-19"},{"cvss_score":9.3,"headline":"WatchGuard Firebox Out-of-Bounds Write","id":"CVE-2025-9242","kev_date_added":"2025-11-12","published":"2025-09-17"},{"cvss_score":8.8,"headline":"WatchGuard Firebox and XTM Privilege Escalation","id":"CVE-2022-23176","kev_date_added":"2022-04-11","published":"2022-02-24"},{"cvss_score":9.8,"headline":"Integer overflow in n/a","id":"CVE-2022-31789","kev_date_added":null,"published":"2022-09-06"},{"cvss_score":9.3,"headline":"Memory corruption in n/a","id":"CVE-2013-6021","kev_date_added":null,"published":"2013-10-19"},{"cvss_score":9.2,"headline":"Fireware OS Code Injection in BOVPN Over TLS Client Allows Remote Code Execution","id":"CVE-2026-86131","kev_date_added":null,"published":"2026-09-29"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Unauthenticated attackers can retrieve sensitive authentication server settings from WatchGuard Firebox and XTM appliances via malicious requests to exposed endpoints.","url":"https://insights.sbomify.com/CVE-2022-31790/"}