{"answers":{"affected":"It affects 17 products.","exploited":"There is no known exploitation of CVE-2022-31800 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-31800 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-31800 is a critical code injection vulnerability in PHOENIX CONTACT AXC 1050, published on 21 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-31800 and fix it if it is affected.\n\nWhat it is: CVE-2022-31800 is a critical code injection vulnerability in PHOENIX CONTACT AXC 1050, published on 21 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-31800 in the wild and no public exploit code.\n\nAffected product: PHOENIX CONTACT AXC 1050. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-31800/ (Markdown: https://insights.sbomify.com/CVE-2022-31800/index.md)","id":"CVE-2022-31800","markdown":"https://insights.sbomify.com/CVE-2022-31800/index.md","name":"CVE-2022-31800","record":{"aliases":["GHSA-m7x4-j34m-52hc"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["code_execution","privilege_escalation"],"network_reachable":"yes","non_default_config":false,"product_category":"Industrial controller","requires_auth":"none","summary":"Unauthenticated attackers can upload malicious logic to PHOENIX CONTACT industrial controllers to gain full device control.","user_interaction":"not_required","vuln_class":"code_injection"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"CERTVDE","cpe":[{"product":"axc_1050_firmware","vendor":"phoenixcontact"},{"product":"axc_1050_xc_firmware","vendor":"phoenixcontact"},{"product":"axc_3050_firmware","vendor":"phoenixcontact"},{"product":"fc_350_pci_eth_firmware","vendor":"phoenixcontact"},{"product":"ilc1x0_firmware","vendor":"phoenixcontact"},{"product":"ilc1x1_firmware","vendor":"phoenixcontact"},{"product":"ilc_1x1_gsm\\/gprs_firmware","vendor":"phoenixcontact"},{"product":"ilc_3xx_firmware","vendor":"phoenixcontact"},{"product":"pc_worx_rt_basic_firmware","vendor":"phoenixcontact"},{"product":"pc_worx_srt_firmware","vendor":"phoenixcontact"},{"product":"rfc_430_eth-ib_firmware","vendor":"phoenixcontact"},{"product":"rfc_450_eth-ib_firmware","vendor":"phoenixcontact"},{"product":"rfc_460r_pn_3tx-s_firmware","vendor":"phoenixcontact"},{"product":"rfc_460r_pn_3tx_firmware","vendor":"phoenixcontact"},{"product":"rfc_470_pn_3tx_firmware","vendor":"phoenixcontact"},{"product":"rfc_470s_pn_3tx_firmware","vendor":"phoenixcontact"},{"product":"rfc_480s_pn_4tx_firmware","vendor":"phoenixcontact"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-345","name":"Insufficient Verification of Data Authenticity"}],"description":"An unauthenticated, remote attacker could upload malicious logic to devices based on ProConOS/ProConOS eCLR in order to gain full control over the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Insufficient Verification of Data Vulnerability in PHOENIX CONTACT classic line industrial controllers","id":"CVE-2022-31800","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"code_injection","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Insufficient Verification of Data Vulnerability in ProConOS/ProConOS eCLR SDK and MULTIPROG Engineering tool","id":"CVE-2022-31801"},"packages":[],"prev":{"headline":"Denial of service in bottle","id":"CVE-2022-31799"},"products":["AXC 1050","AXC 1050 XC","AXC 3050","FC 350 PCI ETH","ILC 1x0","ILC 1x1","ILC 1x1 GSM/GPRS","ILC 3xx","PC WORX RT BASIC","PC WORX SRT","RFC 430 ETH-IB","RFC 450 ETH-IB","RFC 460R PN 3TX","RFC 460R PN 3TX-S","RFC 470 PN 3TX","RFC 470S PN 3TX","RFC 480S PN 4TX"],"published":"2022-06-21","related":[{"cvss_score":9.8,"headline":"Missing authorization in n/a","id":"CVE-2019-9201","kev_date_added":null,"published":"2019-02-26"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2026-06-02","vendors":["PHOENIX CONTACT"]},"summary":"Unauthenticated attackers can upload malicious logic to PHOENIX CONTACT industrial controllers to gain full device control.","url":"https://insights.sbomify.com/CVE-2022-31800/"}