{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-32515 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-32515 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-32515 is a high-severity authentication bypass vulnerability in Schneider Electric Conext™ ComBox, published on 30 Jan 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-32515 and fix it if it is affected.\n\nWhat it is: CVE-2022-32515 is a high-severity authentication bypass vulnerability in Schneider Electric Conext™ ComBox, published on 30 Jan 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-32515 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Conext™ ComBox. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-32515/ (Markdown: https://insights.sbomify.com/CVE-2022-32515/index.md)","id":"CVE-2022-32515","markdown":"https://insights.sbomify.com/CVE-2022-32515/index.md","name":"CVE-2022-32515","record":{"aliases":["GHSA-339h-hwgh-x2jc"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Conext ComBox","requires_auth":"none","summary":"Attackers can brute force the admin account due to missing rate limiting on the authentication form, leading to account takeover.","user_interaction":"not_required","vuln_class":"auth_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"conext_combox_firmware","vendor":"schneider-electric"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N","version":"3.1"},"cwes":[{"id":"CWE-307","name":"Improper Restriction of Excessive Authentication Attempts"}],"description":"A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause brute force attacks to take over the admin account when the product does not implement a rate limit mechanism on the admin authentication form. Affected Products: Conext™ ComBox (All Versions)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Auth bypass in Conext™ ComBox","id":"CVE-2022-32515","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"auth_bypass","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Cross-site request forgery in Conext™ ComBox","id":"CVE-2022-32516"},"packages":[],"prev":{"headline":"Auth bypass in C-Bus Network Automation Controller, LSS5500NAC","id":"CVE-2022-32514"},"products":["Conext™ ComBox"],"published":"2023-01-30","related":[{"cvss_score":7.5,"headline":"Cross-site request forgery in Conext™ ComBox","id":"CVE-2022-32516","kev_date_added":null,"published":"2023-01-30"},{"cvss_score":7.5,"headline":"Information disclosure in Conext� ComBox (All Versions)","id":"CVE-2021-22798","kev_date_added":null,"published":"2022-02-11"},{"cvss_score":6.5,"headline":"Other in Conext™ ComBox","id":"CVE-2022-32517","kev_date_added":null,"published":"2023-01-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-02-05","vendors":["Schneider Electric"]},"summary":"Attackers can brute force the admin account due to missing rate limiting on the authentication form, leading to account takeover.","url":"https://insights.sbomify.com/CVE-2022-32515/"}