{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-32527 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-32527 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-32527 is a critical memory corruption vulnerability in Schneider Electric IGSS Data Server (IGSSdataServer.exe), published on 30 Jan 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-32527 and fix it if it is affected.\n\nWhat it is: CVE-2022-32527 is a critical memory corruption vulnerability in Schneider Electric IGSS Data Server (IGSSdataServer.exe), published on 30 Jan 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-32527 in the wild and no public exploit code.\n\nAffected product: Schneider Electric IGSS Data Server (IGSSdataServer.exe). No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-32527/ (Markdown: https://insights.sbomify.com/CVE-2022-32527/index.md)","id":"CVE-2022-32527","markdown":"https://insights.sbomify.com/CVE-2022-32527/index.md","name":"CVE-2022-32527","record":{"aliases":["GHSA-hfrp-5qw2-x2qm"],"analysis":{"component_type":"ics_ot","fix_type":"upgrade","impacts":["code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"SCADA data server","requires_auth":"none","summary":"Remote attackers can execute arbitrary code via stack-based buffer overflow in IGSS Data Server by sending crafted alarm cache messages.","user_interaction":"not_required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"interactive_graphical_scada_system","vendor":"schneider-electric"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-120","name":"Buffer Copy without Checking Size of Input"}],"description":"A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow, potentially leading to remote code execution when an attacker sends specially crafted alarm cache data messages. Affected Products: IGSS Data Server - IGSSdataServer.exe (Versions prior to V15.0.0.22170)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32527","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Missing authorization in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32528"},"packages":[],"prev":{"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32526"},"products":["IGSS Data Server (IGSSdataServer.exe)"],"published":"2023-01-30","related":[{"cvss_score":10,"headline":"Memory corruption in n/a","id":"CVE-2013-0657","kev_date_added":null,"published":"2013-01-21"},{"cvss_score":9.8,"headline":"Integer overflow in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-2329","kev_date_added":null,"published":"2023-02-01"},{"cvss_score":9.8,"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-24324","kev_date_added":null,"published":"2023-02-01"},{"cvss_score":9.8,"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32522","kev_date_added":null,"published":"2023-01-30"},{"cvss_score":9.8,"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32523","kev_date_added":null,"published":"2023-01-30"},{"cvss_score":9.8,"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32524","kev_date_added":null,"published":"2023-01-30"},{"cvss_score":9.8,"headline":"Memory corruption in IGSS Data Server (IGSSdataServer.exe)","id":"CVE-2022-32525","kev_date_added":null,"published":"2023-01-30"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-02-05","vendors":["Schneider Electric"]},"summary":"Remote attackers can execute arbitrary code via stack-based buffer overflow in IGSS Data Server by sending crafted alarm cache messages.","url":"https://insights.sbomify.com/CVE-2022-32527/"}