{"answers":{"affected":"It affects 7 products.","exploited":"There is no known exploitation of CVE-2022-33175 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-33175 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-33175 is a critical vulnerability in n/a, published on 13 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-33175 and fix it if it is affected.\n\nWhat it is: CVE-2022-33175 is a critical vulnerability in n/a, published on 13 Jun 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-33175 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-33175/ (Markdown: https://insights.sbomify.com/CVE-2022-33175/index.md)","id":"CVE-2022-33175","markdown":"https://insights.sbomify.com/CVE-2022-33175/index.md","name":"CVE-2022-33175","record":{"aliases":["GHSA-x3x3-7q8c-m397"],"analysis":{"component_type":"network_device","fix_type":"upgrade","impacts":["data_read","account_takeover"],"network_reachable":"yes","non_default_config":false,"product_category":"Power Distribution Unit","requires_auth":"none","summary":"Attackers can steal administrator session IDs via an insecure API, enabling unauthorized access to read passwords and reconfigure the device.","user_interaction":"not_required","vuln_class":"information_disclosure"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"basic_pdu_firmware","vendor":"powertekpdus"},{"product":"piml_pdu_firmware","vendor":"powertekpdus"},{"product":"pm_pdu_firmware","vendor":"powertekpdus"},{"product":"smart_pim_firmware","vendor":"powertekpdus"},{"product":"smart_pom_firmware","vendor":"powertekpdus"},{"product":"smart_poms_firmware","vendor":"powertekpdus"},{"product":"smart_pos_firmware","vendor":"powertekpdus"}],"cvss":{"score":9.8,"severity":"critical","source":"cna","vector":"CVSS:3.1/AC:L/AV:N/A:H/C:H/I:H/PR:N/S:U/UI:N","version":"3.1"},"cwes":[{"id":"CWE-732","name":"Incorrect Permission Assignment for Critical Resource"}],"description":"Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 have an insecure permissions setting on the user.token field that is accessible to everyone through the /cgi/get_param.cgi HTTP API. This leads to disclosing active session ids of currently logged-in administrators. The session id can then be reused to act as the administrator, allowing reading of the cleartext password, or reconfiguring the device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Information disclosure in n/a","id":"CVE-2022-33175","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"information_disclosure","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Privilege escalation in Intel(R) NUC 11 Performance kits and Intel(R) NUC 11 Performance Mini PCs","id":"CVE-2022-33176"},"packages":[],"prev":{"headline":"Auth bypass in n/a","id":"CVE-2022-33174"},"products":["n/a"],"published":"2022-06-13","related":[{"cvss_score":9.8,"headline":"Auth bypass in n/a","id":"CVE-2022-33174","kev_date_added":null,"published":"2022-06-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["n/a"]},"summary":"Attackers can steal administrator session IDs via an insecure API, enabling unauthorized access to read passwords and reconfigure the device.","url":"https://insights.sbomify.com/CVE-2022-33175/"}