{"answers":{"affected":"It affects 13 products.","exploited":"There is no known exploitation of CVE-2022-3353 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-3353 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-3353 is a medium-severity denial of service vulnerability in Hitachi Energy FOX61x TEGO1, published on 21 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-3353 and fix it if it is affected.\n\nWhat it is: CVE-2022-3353 is a medium-severity denial of service vulnerability in Hitachi Energy FOX61x TEGO1, published on 21 Feb 2023. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-3353 in the wild and no public exploit code.\n\nAffected product: Hitachi Energy FOX61x TEGO1. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-3353/ (Markdown: https://insights.sbomify.com/CVE-2022-3353/index.md)","id":"CVE-2022-3353","markdown":"https://insights.sbomify.com/CVE-2022-3353/index.md","name":"CVE-2022-3353","record":{"aliases":["GHSA-r27w-hfm7-9mc2"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Hitachi Energy ICS","requires_auth":"none","summary":"An attacker can cause the IEC 61850 MMS-server to stop accepting new connections, disrupting industrial control system communications.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Hitachi Energy","cpe":[{"product":"fox615_tego1_firmware","vendor":"hitachienergy"},{"product":"gms600_firmware","vendor":"hitachienergy"},{"product":"itt600_sa_explorer","vendor":"hitachienergy"},{"product":"modular_switchgear_monitoring_firmware","vendor":"hitachienergy"},{"product":"pwc600_firmware","vendor":"hitachienergy"},{"product":"reb500_firmware","vendor":"hitachienergy"},{"product":"relion_650_firmware","vendor":"hitachienergy"},{"product":"relion_670_firmware","vendor":"hitachienergy"},{"product":"relion_sam600-io_firmware","vendor":"hitachienergy"},{"product":"rtu500_firmware","vendor":"hitachienergy"},{"product":"sys600_firmware","vendor":"hitachienergy"},{"product":"txpert_hub_coretec_4_firmware","vendor":"hitachienergy"},{"product":"txpert_hub_coretec_5_firmware","vendor":"hitachienergy"}],"cvss":{"score":5.9,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-404","name":"Improper Resource Shutdown or Release"}],"description":"A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. \n\nAn attacker could exploit the vulnerability by using a specially crafted message sequence, to force the IEC 61850 MMS-server communication stack, to stop accepting new MMS-client connections. \n\nAlready existing/established client-server connections are not affected.\n\nList of affected CPEs:\n\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r15b08:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16_3:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r2a16:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1e01:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1d02:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1c07:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:fox61x_tego1:r1b02:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:gms600:1.3.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.5.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.6.0.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.7.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:1.8.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.0.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.4:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:itt600_sa_explorer:2.1.0.5:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.2.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.3.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:microscada_x_sys600:10.4.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:mms:2.2.3:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:pwc600:1.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:pwc600:1.1:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:pwc600:1.2:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:reb500:7:*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:reb500:8:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:1.2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:2.0.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:1.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:1.3.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:2.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:2.1.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.1:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relionSAM600-IO:2.2.5:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion670:2.2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:relion650:2.2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:o:hitachienergy:rtu500cmu:12.*.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:rtu500cmu:13.*.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:2.*:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:txpert_hub_coretec_4:3.0:*:*:*:*:*:*:*\n  *  cpe:2.3:a:hitachienergy:txpert_hub_coretec_5:3.0:*:*:*:*:*:*:*","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"IEC 61850 MMS-Server Vulnerability in multiple Hitachi Energy Products","id":"CVE-2022-3353","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2022"},"n_packages":0,"n_references":10,"next":{"headline":"Open5GS UDP Packet ogs-tlv-msg.c denial of service","id":"CVE-2022-3354"},"packages":[],"prev":{"headline":"Use After Free in vim/vim","id":"CVE-2022-3352"},"products":["FOX61x TEGO1","GMS600","ITT600 SA Explorer","MSM","MicroSCADA X SYS600","PWC600","REB500","RTU500","Relion® 650","Relion® 670","SAM600-IO","TXpert Hub CoreTec 4","TXpert Hub CoreTec 5"],"published":"2023-02-21","related":[{"cvss_score":7.5,"headline":"Specially Crafted IEC 61850 Protocol Sequence Vulnerability","id":"CVE-2021-27196","kev_date_added":null,"published":"2021-06-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-03-12","vendors":["Hitachi Energy"]},"summary":"An attacker can cause the IEC 61850 MMS-server to stop accepting new connections, disrupting industrial control system communications.","url":"https://insights.sbomify.com/CVE-2022-3353/"}