CVE-2022-34753 Command injection in SpaceLogic C-Bus Home Controller

High 8.8 Published Updated

Remote attackers can execute arbitrary OS commands with root privileges on Schneider Electric SpaceLogic C-Bus Home Controllers.

Exploited in the wild
Not known
Login needed
Any signed-in user
Attackable
Over the internet
Victim action needed
Not needed
Fix
None listed

What is CVE-2022-34753?

CVE-2022-34753 is a high-severity command injection vulnerability in Schneider Electric SpaceLogic C-Bus Home Controller, published on 13 Jul 2022. Any signed-in user can exploit it over the network, with no action from the victim.

Official description

A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)

Weakness: CWE-78

Which versions are affected by CVE-2022-34753?

It affects 1 product.

Products include Schneider-Electric Spacelogic C-Bus Home Controller Firmware.

How do I fix CVE-2022-34753?

No fix has been published for CVE-2022-34753 yet. Limit exposure of the affected software until one is available.

Upgrade, and pass arguments to programs as a list instead of through a shell. More about Command injection.

Is CVE-2022-34753 being exploited?

It is not confirmed as exploited in the wild, but public exploit code for CVE-2022-34753 exists.

Public exploit code: 1 Nuclei template.

Sources

Also known as GHSA-mx84-3frj-x7gc.

Is CVE-2022-34753 in your software?

Upload an SBOM and sbomify checks it against every vulnerability here, every day.

Check your SBOMs for free