{"answers":{"affected":"It affects 2 products.","exploited":"There is no known exploitation of CVE-2022-34754 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-34754 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-34754 is a medium-severity vulnerability in Schneider Electric Acti9 PowerTag Link C, published on 13 Jul 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-34754 and fix it if it is affected.\n\nWhat it is: CVE-2022-34754 is a medium-severity vulnerability in Schneider Electric Acti9 PowerTag Link C, published on 13 Jul 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-34754 in the wild and no public exploit code.\n\nAffected product: Schneider Electric Acti9 PowerTag Link C. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-34754/ (Markdown: https://insights.sbomify.com/CVE-2022-34754/index.md)","id":"CVE-2022-34754","markdown":"https://insights.sbomify.com/CVE-2022-34754/index.md","name":"CVE-2022-34754","record":{"aliases":["GHSA-hjr4-3w43-ggw8"],"analysis":{"component_type":"iot_embedded","fix_type":"upgrade","impacts":["privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"PowerTag Link C","requires_auth":"none","summary":"Attackers can gain elevated privileges by guessing credentials on Schneider Electric Acti9 PowerTag Link C devices.","user_interaction":"not_required","vuln_class":"privilege_escalation"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"acti9_powertag_link_c_\\(a9xelc10-a\\)_firmware","vendor":"schneider-electric"},{"product":"acti9_powertag_link_c_\\(a9xelc10-b\\)_firmware","vendor":"schneider-electric"}],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-269","name":"Improper Privilege Management"}],"description":"A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior)","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Privilege escalation in Acti9 PowerTag Link C","id":"CVE-2022-34754","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"privilege_escalation","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Path traversal in Easergy Builder Installer","id":"CVE-2022-34755"},"packages":[],"prev":{"headline":"Command injection in SpaceLogic C-Bus Home Controller","id":"CVE-2022-34753"},"products":["Acti9 PowerTag Link C"],"published":"2022-07-13","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-09-17","vendors":["Schneider Electric"]},"summary":"Attackers can gain elevated privileges by guessing credentials on Schneider Electric Acti9 PowerTag Link C devices.","url":"https://insights.sbomify.com/CVE-2022-34754/"}