{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-36385 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-36385 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-36385 is a medium-severity vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-36385 and fix it if it is affected.\n\nWhat it is: CVE-2022-36385 is a medium-severity vulnerability in CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor, published on 13 Sep 2022. It can only be exploited from the same machine or local network, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-36385 in the wild and no public exploit code.\n\nAffected product: CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-36385/ (Markdown: https://insights.sbomify.com/CVE-2022-36385/index.md)","id":"CVE-2022-36385","markdown":"https://insights.sbomify.com/CVE-2022-36385/index.md","name":"CVE-2022-36385","record":{"aliases":["GHSA-gvx4-5vjq-6x82"],"analysis":{"component_type":"iot_embedded","fix_type":"no_fix_stated","impacts":["code_execution","privilege_escalation"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"patient monitor","requires_auth":"none","summary":"An attacker with physical access can bypass authentication to install malicious firmware on Contec Health CMS8000 patient monitors via USB.","user_interaction":"not_required","vuln_class":"security_feature_bypass"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"icscert","cpe":[{"product":"cms8000_firmware","vendor":"contechealth"}],"cvss":{"score":6.8,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"cwes":[{"id":"CWE-284","name":"Improper Access Control"}],"description":"A threat actor with momentary access to the device can plug in a USB drive and perform a malicious firmware update, resulting in permanent changes to device functionality. No authentication or controls are in place to prevent a threat actor from maliciously modifying firmware and performing a drive-by attack to load the firmware on any CMS8000 device.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Contec Health CMS8000","id":"CVE-2022-36385","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"security_feature_bypass","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Code injection in Import any XML or CSV File to WordPress (WordPress plugin)","id":"CVE-2022-36386"},"packages":[],"prev":{"headline":"Privilege escalation in Intel(r) NUC Kit Wireless Adapter drivers for Windows 10","id":"CVE-2022-36384"},"products":["CMS8000 CONTEC ICU CCU Vital Signs Patient Monitor"],"published":"2022-09-13","related":[{"cvss_score":7.5,"headline":"Contec Health CMS8000","id":"CVE-2022-38100","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":5.7,"headline":"Contec Health CMS8000","id":"CVE-2022-3027","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":4.3,"headline":"Contec Health CMS8000","id":"CVE-2022-38069","kev_date_added":null,"published":"2022-09-13"},{"cvss_score":3,"headline":"Contec Health CMS8000","id":"CVE-2022-38453","kev_date_added":null,"published":"2022-09-13"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Contec Health"]},"summary":"An attacker with physical access can bypass authentication to install malicious firmware on Contec Health CMS8000 patient monitors via USB.","url":"https://insights.sbomify.com/CVE-2022-36385/"}