{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-37302 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-37302 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-37302 is a medium-severity memory corruption vulnerability in Schneider Electric EcoStruxure Control Expert, published on 13 Sep 2022. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-37302 and fix it if it is affected.\n\nWhat it is: CVE-2022-37302 is a medium-severity memory corruption vulnerability in Schneider Electric EcoStruxure Control Expert, published on 13 Sep 2022. It can only be exploited from the same machine or local network, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-37302 in the wild and no public exploit code.\n\nAffected product: Schneider Electric EcoStruxure Control Expert. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-37302/ (Markdown: https://insights.sbomify.com/CVE-2022-37302/index.md)","id":"CVE-2022-37302","markdown":"https://insights.sbomify.com/CVE-2022-37302/index.md","name":"CVE-2022-37302","record":{"aliases":["GHSA-mp38-wwj7-h8qj"],"analysis":{"component_type":"desktop_application","fix_type":"upgrade","impacts":["denial_of_service"],"network_reachable":"adjacent_or_local","non_default_config":false,"product_category":"Industrial control software","requires_auth":"none","summary":"An attacker can cause a crash in EcoStruxure Control Expert by tricking a user into opening a malicious project file.","user_interaction":"required","vuln_class":"memory_corruption"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"schneider","cpe":[{"product":"ecostruxure_control_expert","vendor":"schneider-electric"}],"cvss":{"score":5.5,"severity":"medium","source":"cna","vector":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-119","name":"Improper Restriction of Operations within the Bounds of a Memory Buffer"}],"description":"A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior).","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Memory corruption in EcoStruxure Control Expert","id":"CVE-2022-37302","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"memory_corruption","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2022-37303"},"packages":[],"prev":{"headline":"Integer overflow in Legacy Modicon Quantum/Premium","id":"CVE-2022-37301"},"products":["EcoStruxure Control Expert"],"published":"2022-09-13","related":[{"cvss_score":9.8,"headline":"Auth bypass in EcoStruxure Control Expert","id":"CVE-2022-37300","kev_date_added":null,"published":"2022-09-12"},{"cvss_score":9.8,"headline":"Auth bypass in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)","id":"CVE-2020-28212","kev_date_added":null,"published":"2020-11-19"},{"cvss_score":9.8,"headline":"Code injection in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10)","id":"CVE-2020-7475","kev_date_added":null,"published":"2020-03-23"},{"cvss_score":8.8,"headline":"Other in EcoStruxure Control Expert","id":"CVE-2023-27976","kev_date_added":null,"published":"2023-04-18"},{"cvss_score":8.8,"headline":"Code injection in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions)","id":"CVE-2020-28213","kev_date_added":null,"published":"2020-11-19"},{"cvss_score":8.6,"headline":"Memory corruption in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions)","id":"CVE-2020-7560","kev_date_added":null,"published":"2020-12-11"},{"cvss_score":8.1,"headline":"Other in EcoStruxure Control Expert","id":"CVE-2023-6408","kev_date_added":null,"published":"2024-02-14"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":null,"exploitation":null,"technical_impact":null},"state":"PUBLISHED","updated":"2024-08-03","vendors":["Schneider Electric"]},"summary":"An attacker can cause a crash in EcoStruxure Control Expert by tricking a user into opening a malicious project file.","url":"https://insights.sbomify.com/CVE-2022-37302/"}