{"answers":{"affected":"It affects 1 product.","exploited":"There is no known exploitation of CVE-2022-37461 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-37461 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-37461 is a medium-severity cross-site scripting vulnerability in n/a, published on 30 Sep 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link."},"fix_prompt":"Check this codebase for CVE-2022-37461 and fix it if it is affected.\n\nWhat it is: CVE-2022-37461 is a medium-severity cross-site scripting vulnerability in n/a, published on 30 Sep 2022. An attacker can exploit it over the internet without logging in, and only if a user opens a file or follows a link.\nExploitation: There is no known exploitation of CVE-2022-37461 in the wild and no public exploit code.\n\nAffected product: n/a. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-37461/ (Markdown: https://insights.sbomify.com/CVE-2022-37461/index.md)","id":"CVE-2022-37461","markdown":"https://insights.sbomify.com/CVE-2022-37461/index.md","name":"CVE-2022-37461","record":{"aliases":["GHSA-7p78-28rx-wm6c"],"analysis":{"component_type":"web_application","fix_type":"upgrade","impacts":["data_read","code_execution"],"network_reachable":"yes","non_default_config":false,"product_category":"Medical imaging viewer","requires_auth":"none","summary":"Remote attackers can inject scripts to steal patient data or execute code in Canon Medical Vitrea View via vulnerable parameters.","user_interaction":"required","vuln_class":"xss"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"mitre","cpe":[{"product":"medical_vitrea_view","vendor":"canon"}],"cvss":{"score":6.1,"severity":"medium","source":"cisa-adp","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","version":"3.1"},"cwes":[{"id":"CWE-79","name":"Improper Neutralization of Input During Web Page Generation"}],"description":"Multiple cross-site scripting (XSS) vulnerabilities in Canon Medical Vitrea View 7.x before 7.7.6 allow remote attackers to inject arbitrary web script or HTML via (1) the input after the error subdirectory to the /vitrea-view/error/ subdirectory, or the (2) groupID, (3) offset, or (4) limit parameter to an Administrative Panel (Group and Users) page. There is a risk of an attacker retrieving patient information.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Cross-site scripting in n/a","id":"CVE-2022-37461","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"xss","year":"2022"},"n_packages":0,"n_references":3,"next":{"headline":"Cross-site scripting in n/a","id":"CVE-2022-37462"},"packages":[],"prev":{"headline":"DO NOT USE THIS CANDIDATE NUMBER.","id":"CVE-2022-37460"},"products":["n/a"],"published":"2022-09-30","related":[],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"no","exploitation":"none","technical_impact":"total"},"state":"PUBLISHED","updated":"2025-05-20","vendors":["n/a"]},"summary":"Remote attackers can inject scripts to steal patient data or execute code in Canon Medical Vitrea View via vulnerable parameters.","url":"https://insights.sbomify.com/CVE-2022-37461/"}