{"answers":{"affected":"It affects 5 products.","exploited":"There is no known exploitation of CVE-2022-3752 in the wild and no public exploit code.","fix":"No fix has been published for CVE-2022-3752 yet. Limit exposure of the affected software until one is available.","what":"CVE-2022-3752 is a high-severity denial of service vulnerability in Rockwell Automation Compact GuardLogix 5380, published on 19 Dec 2022. An attacker can exploit it over the internet without logging in, with no action from the victim."},"fix_prompt":"Check this codebase for CVE-2022-3752 and fix it if it is affected.\n\nWhat it is: CVE-2022-3752 is a high-severity denial of service vulnerability in Rockwell Automation Compact GuardLogix 5380, published on 19 Dec 2022. An attacker can exploit it over the internet without logging in, with no action from the victim.\nExploitation: There is no known exploitation of CVE-2022-3752 in the wild and no public exploit code.\n\nAffected product: Rockwell Automation Compact GuardLogix 5380. No package-level version data is available, so check the vendor advisory linked from the reference page.\n\nTask:\n1. Search the dependency manifests and lockfiles (for example package.json, package-lock.json, requirements.txt, poetry.lock, uv.lock, pom.xml, build.gradle, go.mod, Cargo.lock, Gemfile.lock) and any Dockerfiles for the affected packages, including transitive dependencies.\n2. If an affected version is in use, upgrade it to the fixed version for its release line with the project's package manager, so the lockfile is regenerated. Prefer the smallest upgrade that fixes it.\n3. If there is no fix, or the upgrade would break the build, do not guess: explain the risk and the safest workaround instead.\n4. Run the tests and summarise what changed and why.\n5. If nothing in the project is affected, say so and change nothing.\n\nReference: https://insights.sbomify.com/CVE-2022-3752/ (Markdown: https://insights.sbomify.com/CVE-2022-3752/index.md)","id":"CVE-2022-3752","markdown":"https://insights.sbomify.com/CVE-2022-3752/index.md","name":"CVE-2022-3752","record":{"aliases":["GHSA-q432-7rqq-8cfj"],"analysis":{"component_type":"ics_ot","fix_type":"patch","impacts":["denial_of_service"],"network_reachable":"yes","non_default_config":false,"product_category":"Rockwell Logix controllers","requires_auth":"none","summary":"An attacker can cause a denial-of-service condition in Rockwell Logix controllers by sending crafted Ethernet/IP messages, requiring manual recovery.","user_interaction":"not_required","vuln_class":"denial_of_service"},"analysis_generated_by":"qwen3.8-flash-next","assigner":"Rockwell","cpe":[{"product":"compact_guardlogix_5380_firmware","vendor":"rockwellautomation"},{"product":"compactlogix_5380_firmware","vendor":"rockwellautomation"},{"product":"compactlogix_5480_firmware","vendor":"rockwellautomation"},{"product":"compactlogix_5580_firmware","vendor":"rockwellautomation"},{"product":"guardlogix_5580_firmware","vendor":"rockwellautomation"}],"cvss":{"score":8.6,"severity":"high","source":"cna","vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H","version":"3.1"},"cwes":[{"id":"CWE-20","name":"Improper Input Validation"}],"description":"An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic \nloading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload \nthe user project file to bring the device back online and continue normal operation.","ecosystems":[],"exploits":{"exploitdb":0,"first_seen":null,"github_poc":0,"max_poc_stars":null,"metasploit":0,"nuclei":0,"refs":[],"tier":"none_known"},"has_fix":null,"headline":"Rockwell Automation GuardLogix and ControlLogix controllers Vulnerable to Denial-Of-Service Attack","id":"CVE-2022-3752","indexable":true,"kev":null,"kind":"cve","links":{"ecosystem":null,"product":null,"products":[],"type":"denial_of_service","year":"2022"},"n_packages":0,"n_references":1,"next":{"headline":"Evaluate \u003c= 1.0 - Admin+ Stored Cross-Site Scripting","id":"CVE-2022-3753"},"packages":[],"prev":{"headline":"SQL Injection in owncast/owncast","id":"CVE-2022-3751"},"products":["Compact GuardLogix 5380","CompactLogix 5380","CompactLogix 5480","ControlLogix 5580 ","GuardLogix 5580"],"published":"2022-12-19","related":[{"cvss_score":7.7,"headline":"Rockwell Automation Studio 5000 Logix Designer Code Injection","id":"CVE-2022-1159","kev_date_added":null,"published":"2022-04-01"}],"sources":[{"class":"attribution","licence":"CVE Terms of Use (MITRE)","name":"CVE List","prefix":"CVE"},{"class":"attribution","licence":"US public information, NVD API terms","name":"NVD"},{"class":"attribution","licence":"CWE Terms of Use","name":"CWE (MITRE)"},{"class":"attribution","licence":"FIRST CVSS licence","name":"CVSS (FIRST)"}],"ssvc":{"automatable":"yes","exploitation":"none","technical_impact":"partial"},"state":"PUBLISHED","updated":"2025-04-16","vendors":["Rockwell Automation"]},"summary":"An attacker can cause a denial-of-service condition in Rockwell Logix controllers by sending crafted Ethernet/IP messages, requiring manual recovery.","url":"https://insights.sbomify.com/CVE-2022-3752/"}